AP-1600T-USB | AP-3200T-USB | User Manual (Ver. 2.0)
Setting List (Feature Properties)
- 86 -
Sequencer Control Item
Setting Range
Default
Description
SequencerSetStart
1 ~ 128
1
Configure the index number to execute at the
start of TriggerSequencer mode.
SequencerReset
-
-
In TriggerSequencerMode, reset the current
index number to the number configured in
SequencerSetStart.
ChunkDataControl
Configure Chunk Control settings.
Related Topic:
Chunk Data Control Items
Setting
Range
Default
Description
ChunkModeActive
0: False
1: True
0: False
Set whether to enable ChunkData.
ChunkSelector
-
OffsetX
Selects which Chunk to enable or control. Options are as follows.
ChunkEnable
0: False
1: True
0: False
Enables the inclusion of the selected Chunk data in the payload of
the image.
ChunkOffsetX
-
-
Dispaly the OffsetX value (
).
ChunkID: 0x2000
ChunkOffsetY
-
-
Dispaly the OffsetY value (
).
ChunkID: 0x2001
ChunkWidth
-
-
Dispaly the Width value (
).
ChunkID: 0x2002
ChunkHeight
-
-
Dispaly the Height value (
).
ChunkID: 0x2003
ChunkPixelFormat
-
-
Dispaly the PixelFormat value (
).
ChunkID: 0x2012
ChunkTimestamp
-
-
Dispaly the Timestamp value (
).
ChunkID: 0x2014
ChunkLineStatusAll
-
-
Display the LineStatusAll (
) value. The data
acquisition timing is on the falling edge of FVAL, and the displayed
value is the value determined by the Line Inverter setting.
ChunkID: 0x2013
ChunkExposureTimeMode
-
-
Display the ExposureTimeMode (
) value.
ChunkID: 0x201B