MasterMode
AnalogAll : 0dB 〜 18dB
AnalogRed : -6.5dB 〜 12dB
AnalogBlue : -6.5dB 〜 12dB
DigitalRed : -0.915dB 〜 0.828dB
DigitalBlue : -0.915dB 〜 0.828dB
IndividualMode
AnalogAll : 0dB 〜 36.13dB
AnalogRed : 0dB 〜 36.13dB
AnalogBlue : 0dB 〜 36.13dB
DigitalRed : -0.915dB 〜 0.828dB
DigitalBlue : -0.915dB 〜 0.828dB
Off, Continuous, Once
DigitalRed, DigitalBlue : -7dB 〜 15dB
Off, Continuous, Once, ExposureOnce, ExposureContinuos,
Preset3200K, Preset5000K, Preset6500K, Preset7500K
16 (4 x 4) Area
3000K 〜 9000K
Detect white blemishes using threshhold values
(100 steps available)
(black blemish correction performed only at factory)
Interpolation using adjacent pixels
(continuous blemishes not corrected)
1736 pixels / sensor
Video level adjusted automatically using AGC and ASC
0.45,0.5,0.55,0.6,0.65,0.75,0.8,0.9,1.0
(9 steps available)
OFF︓γ= 1.0,ON = 257 points can be set
3G(20 Hz 〜 200 Hz X-Y-Z direction)
50G
Input range
DC + 10 V 〜+ 25 V (Via input terminal)
Consumption
11.6 W(typ.)
(at 12 V input, default setting, 25 ℃ environment)
15.3 W(max.)
C-mount
Lens mount protrusion length of 4 mm or less is supported
17.526, tolerance: 0 mm to -0.05 mm
IR cut filter (Sensor 0/Stream 0)
5℃〜+ 45℃ / 20%〜 80%(non-condensing)
(* It may change depending on the installation environment. Please refer to the Caution.)
25℃〜+ 60℃ / 20%〜 80%(non-condensing)
CE(EN 55032:2015, EN 55035:2017),
FCC part 15 class B, RoHS, WEEE
62 × 62 × 86.5mm (WHD) (excluding mount protrusions)
270 g
Dimensions (housing)
Weight
Verified performance temperature / humidity
Storage temperature / humidity
Regulations
Lens mount
Flange back
Optical filter
Power supply 12-pin Connector
LUT
Vibration resistance
Impact resistance
ALC
Gamma
Blemish
correction
Detection
Correction
Correctable pixels
White
balance
WhiteBalanceGain
BalanceWhiteAuto
Photometry area
Adjustment range
Manual adjustment range
Gain
adjustment
adjustment Auto gain
— 69 —
AP-3200T-10GE
Package contentsCamera
body (1)
Sensor protection cap (1)
Dear Customer (sheet) (1)
Optional accessories (not supplied)
MP-42 tripod mount
Design and specifications are subject to change without notice.
Approximately 30 minutes of warm-up are required to achieve these specifications.
About the verified performance temperature, make sure the following temperature
condition is met when operating the unit.
1) The camera's internal temperature sensor detects temperatures of 101°C or less
during operation.
If the above temperature conditions are exceeded, take measures to dissipate heat
according to your installation environment and conditions.
Caution