Setting range
Default value
Description
Configure sequencer settings.
Off, On
Off
Enable/disable [SequencerMode].
0:TriggerSequencerMode,
1:CommandSequencerMode
TriggerSequencerMode
Select the sequencer mode.
1〜128
1
Select the index number to configure.
SequencerWidth
16〜2064 step 16
2064
Set the width of the selected SequencerIndex.
SequencerHeight
8〜1544 step 4
1544
Set the height of the selected SequencerIndex.
SequencerOffsetX
0〜2064 step 16
0
Set the horizontal offset value for the selected SequencerIndex.
SequencerOffsetY
0〜1544 step 4
0
Set the vertical offset value for the selected SequencerIndex.
SequencerBinningHorizontal
0, 1
0
For the selected SequencerIndex, set the number of pixels in the horizontal
direction for which to perform binning.
In binning mode, the setting value of BinningHorizontalMode is applied.
SequencerBinningVertical
0, 1
0
For the selected SequencerIndex, set the number of pixels in the vertical
direction for which to perform binning.
In binning mode, the setting of BinningVerticalMode is applied.
SequencerFrameCount
ー
ー
Set the FrameCount value for the selected SequencerIndex.
SequencerExposureTime
1μs 〜
ー
Set the exposure time for the selected SequencerIndex.
SequencerGainAnalogAll
x1.0 〜 x16.0
x1.0
Set the GainAnalogAll value.
SequencerGainDigitalRed
x0.447〜x5.624
x1.0
Set the DigitalRed Gain value for the selected SequencerIndex.
SequencerGainDigitalBlue
x0.447〜x5.624
x1.0
Set the DigitalBlue Gain value for the selected SequencerIndex.
SequencerBlackLevelAll
-133〜255
0
Set the BlackLevelAll value for the selected SequencerIndex.
SequencerLutEnable
True, False
False
Set the LutEnable value for the selected SequencerIndex.
SequencerSetNext
0 〜 128
Set the next index to be displayed for the selected SequencerIndex.
(Enabled only for TriggerSequencer.)
If 0 is specified, the operation of Sequencer is stopped.
1〜255
1
Set the repeat count for the sequencer.
1〜128
1
Displays the sequencer set number.
1〜128
1
Specify the first index number to switch to when starting
[TriggerSequencerMode].
1〜128
1
Set this to change the SequencerIndex. (Enabled only for
CommandSequencer.)
ー
ー
In [TriggerSequencerMode], reset the current index number to the number
configured in [SequencerSetStart].
Configure counter settings.
(This camera only supports counter functions.)
0: Counter0
1: Counter1
2: Counter2
3: Counter3
ー
Select the counter.
CounterEventSource
ー
Off
Assign the counter event signal for which you want to read the count value
to a dedicated counter, and read the value.
[Setting range]
Counter0 0:Off, 1:FrameTrigger
Counter1 0:Off, 1:ExposureStart
Counter2 0:Off, 1:SensorReadOut
Counter3 0:Off, 1:FrameTransferEnd
CounterEventActivation
ー
ー
Set the count timing.
The setting value is fixed with the following data.
Counter0 RisingEdge
Counter1 RisingEdge
Counter2 RisingEdge
Counter3 FallingEdge
CounterReset
ー
ー
Reset the counter.
CounterValue
0〜65535
0
Display the count value.
CounterStatus
ー
ー
Display the counter status.
0: CounterIdle: Idle
1: CounterTriggerWait
2: CounterActive: Counting
3: CounterCompleted:Complete counting
4: CounterOverflow: Count value exceeded the maximum valule.
Configure settings for action control.
0x00000000〜
0xFFFFFFFF
ー
An action command is executed if this ActionDeviceKey matches the
DeviceKey contained in the action command message.
Indicates the size of ActionQueue.
1,2
1
Select the ActionSelector.
ActionGroupMask
0x00000000〜
0xFFFFFFFF
ー
An action command is executed if the result of an AND operation of
GroupMask contained in this ActionGroupMask and an action command
message is not 0.
ActionGroupKey
0x00000000〜
0xFFFFFFFF
ー
An action command is executed if this ActionGroupKey matches the
GroupKey contained in the action command message.
SequencerControl
CounterAndTimerControl
ActionControl
SequencerSetSelector
SequencerModeSelect
SequencerMode
ActionQueueSize
SequencerSetStart
SequencerCommandIndex
ActionDeviceKey
ActionSelector
CounterSelector
SequencerReset
SequencerSetActive
SequencerRepetition
Item
—
64
—