— 34 —
Acquisition
Control
Maximum frame rate period formula
Calculate H_Period (number of clocks) from H_Period.
H_Period(number of clocks) = ROUNDUP(H_Period × 74.25, 0)
Maximum frame rate
= 74.25 × 1000000 ÷ ( H_Period(number of clocks) × ( 40) )