B
LDU ERROR CODES
en-129
Safety, Operation, & Maintenance Manual
Lithium
Msg Timeout Consumer0:
No heartbeat message was received
within the timeout time from the
node.
Msg Timeout Consumer1:
No heartbeat message was received
within the timeout time from the
node.
Msg Timeout Consumer2:
No heartbeat message was received
within the timeout time from the
node.
Msg Timeout Consumer3:
No heartbeat message was received
within the timeout time from the
node.
NMT Safe State Error:
20 ms has passed since the main
CPU has detected the NMT safe
state event but this CPU has not
detected the NMT safe state event.
Checksum Error:
There is a checksum error on any
EEPROM segment with checksum.
Independent Watchdog Timeout:
The MCU internal independent
watchdog was not reset in time
causing the MCU to reset.
Windowed Watchdog Timeout:
The MCU internal windowed
watchdog was not reset in time
causing the MCU to reset.
Execution Time High 4kHz:
The average execution time was
higher than 200U us.
Execution Time High 50Hz:
The average execution time was
higher than 6000U us.
LDU Error Code
Description
Caution
LED
Alarm
Sound
-
ing
Engine
Stop
Traction
Stop
Mow Stop
On Off Yes No Yes No Yes No Yes No
STEERING
FAULT F03A
STEERING
FAULT F03B
STEERING
FAULT F03C
STEERING
FAULT F03D
STEERING
FAULT F040
STEERING
FAULT F051
STEERING
FAULT F053
STEERING
FAULT F054
STEERING
FAULT F055
STEERING
FAULT F056
Содержание 10029194
Страница 14: ...en 14 Safety Operation Maintenance Manual Notes Lithium SPECIFICATIONS...
Страница 18: ...en 18 Safety Operation Maintenance Manual DECALS Notes Lithium...
Страница 44: ...en 44 Safety Operation Maintenance Manual CONTROLS Notes Lithium...
Страница 62: ...en 62 Safety Operation Maintenance Manual BATTERIES Notes Lithium...
Страница 88: ...en 88 Safety Operation Maintenance Manual ADJUSTMENTS Notes Lithium...
Страница 146: ...en 146 Safety Operation Maintenance Manual QUALITY OF CUT Notes Lithium...
Страница 147: ......