
B
LDU ERROR CODES
en-103
Safety, Operation, & Maintenance Manual
Lithium
Curr Meas When Off Ch6:
More than 200 mA of current is
detected when the output should be
off.
Load Active When ODO Off Ch1:
The system detected that the voltage
drop is active across the load when
OD is off. This indicates that the
open drain has a short circuit to B-.
Load Active When Off ODO Ch2:
The system detected that the voltage
drop is active across the load when
OD is off. This indicates that the
open drain has a short circuit to B-.
Load Active When Off ODO Ch3:
The system detected that the voltage
drop is active across the load when
OD is off. This indicates that the
open drain has a short circuit to B-.
High Side Short Circuit:
A hardware short circuit is detected.
Disabling of the output is required to
clear the fault.
High Side Input Low:
The system detected that the high
side input is low. This indicates that
the high side input is not connected
or has a short circuit to B-.
LDU Error Code
Description
Caution
LED
Alarm
Sound
-
ing
Engine
Stop
Traction
Stop
Mow Stop
On Off Yes No Yes No Yes No Yes No
TRACTION
FAULT 5466
3WD TRACTION
FAULT 5466
TRACTION
FAULT 5481
3WD TRACTION
FAULT 5481
TRACTION
FAULT 5482
TRACTION
FAULT 5483
3WD TRACTION
FAULT 5483
TRACTION
FAULT 5500
STEERING
FAULT 5500
3WD TRACTION
FAULT 5500
TRACTION
FAULT 5501
3WD TRACTION
FAULT 5501
Содержание 10029194
Страница 14: ...en 14 Safety Operation Maintenance Manual Notes Lithium SPECIFICATIONS...
Страница 18: ...en 18 Safety Operation Maintenance Manual DECALS Notes Lithium...
Страница 44: ...en 44 Safety Operation Maintenance Manual CONTROLS Notes Lithium...
Страница 62: ...en 62 Safety Operation Maintenance Manual BATTERIES Notes Lithium...
Страница 88: ...en 88 Safety Operation Maintenance Manual ADJUSTMENTS Notes Lithium...
Страница 146: ...en 146 Safety Operation Maintenance Manual QUALITY OF CUT Notes Lithium...
Страница 147: ......