17
07610-003-61-42-T
DELIME INSTRUCTIONS
OPERATION
To proceed with the delime operation, fi ll the dishmachine with the correct amount of
delime solution as recommended by the chemical manufacturer. The tank capacities
of the machine can be found in the Specifi cations section of this manual.
After the chemicals are added, perform the following steps:
1. Disconnect or turn off chemical feeder pumps.
2. Close the door.
3. Flip the Auto/Manual Switch to Manual.
4. Run the machine for the length of time required by the chemical solution
manufacturer.
5. Flip the Auto/Manual Switch to Auto to shut the unit off.
6. Open the door and step away for 5 minutes.
7. Inspect the inside of the unit to determine if your expectations have been met. If
not, you may need to run the delime solution through the unit again.
8. Once clean, place the Auto/Manual switch in Auto and turn the Power Switch off.
9. Drain the machine completely.
10. Close the door.
11. Place the Power Switch in the ON position to refi ll the unit.
12. Run the unit in Manual for 10 minutes.
13. Press the Power Switch to turn the unit off.
14. Open the door.
15. Drain the unit.
16. Flip the Auto/Manual Switch to Auto.
17. Your machine is ready to use.
This equipment is not recommended for use with deionized water or other
aggressive fl uids. Use of deionized water or other aggressive fl uids will result
in corrosion and failure of materials and components. Use of deionized water
or other aggressive fl uids will void the manufacturer’s warranty.
DELIME
INSTRUCTIONS
Auto/Manual Switch
Power Switch
Содержание TEMPSTAR
Страница 2: ......
Страница 31: ...24 07610 003 61 42 T TOP CONTROL BOX ASSEMBLY PARTS Continued 26 1 29 28 30 33 34 36 ...
Страница 66: ...59 07610 003 61 42 T PARTS TEMPSTAR VENTLESS SYSTEM ASSEMBLY ...
Страница 74: ...07610 003 61 42 T 67 SCHEMATICS SOLID STATE 208 230V 50 60 HZ 1 3 PHASE TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 75: ...07610 003 61 42 T TEMPSTAR 208 230V 50 60 HZ 1 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES 68 ...
Страница 76: ...69 07610 003 61 42 T SCHEMATICS SOLID STATE 460 V 60 HZ 3 PHASE TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 77: ...70 TEMPSTAR 460 V 60 HZ 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 79: ...72 TEMPSTAR LT NB 208 230V 50 60HZ 1 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 80: ...73 07610 003 61 42 T SCHEMATICS TEMPSTAR NB LT 460V 50 60 HZ 3 PHASE TOP MOUNT UNIVERSAL TIMER ...
Страница 82: ...75 07610 003 61 42 T SCHEMATICS SDI OPTIONS ...
Страница 83: ...76 07610 003 61 42 T DRAIN QUENCH OPTIONS SCHEMATICS ...
Страница 85: ......