INSTALLATION
ELECTRICAL POWER
CONNECTIONS
Electrical and grounding connections must comply with the applicable portions of the
National Electrical Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
Disconnect electrical power supply and place a tag at the disconnect switch to indicate
that you are working on the circuit.
The dishmachine data plate is located on the right side and to the front of the machine.
Refer to the data plate for machine operating requirements, machine voltage, total
amperage load and serial number.
To install the incoming power lines, open
the control box. This will require taking
a phillipshead screwdriver and removing
the four (4) screws on the front cover of
the control box. Install 3/4” conduit into
the pre-punched holes in the back of
the control box. Route power wires and
connect to power block and grounding
lug. Install the service wires (L1, L2, and
L3 (3 phase only)) to the appropriate
terminals as they are marked on the
terminal block. Install the grounding
wire into the lug provided. Tighten the
connections. It is recommended that
“DE-OX” or another similar anti-oxidation
agent be used on all power connections.
Ensure that the power switch is in the OFF position and apply power to the dishmachine.
Check the incoming power at the terminal block and ensure it corresponds to the
voltage listed on the data plate. If not, contact a qualifi ed service agency to examine
the problem. Do not run the dishmachine if the voltage is too high or too low. Shut
off the service breaker and mark it as being for the dishmachine. Advise all proper
personnel of any problems and of the location of the service breaker. Replace the
control box cover and tighten down the screws.
DISCONNECT ELECTRICAL
POWER SUPPLIES & TAG
OUT IN ACCORDANCE
WITH APPROPRIATE
PROCEDURES & CODES
AT THE DISCONNECT
SWITCH TO INDICATE
THE CIRCUIT IS BEING
SERVICED.
VOLTAGE CHECK
Power Block
Ground Lug
Incoming Power Connection
Содержание TEMPSTAR
Страница 2: ......
Страница 31: ...24 07610 003 61 42 T TOP CONTROL BOX ASSEMBLY PARTS Continued 26 1 29 28 30 33 34 36 ...
Страница 66: ...59 07610 003 61 42 T PARTS TEMPSTAR VENTLESS SYSTEM ASSEMBLY ...
Страница 74: ...07610 003 61 42 T 67 SCHEMATICS SOLID STATE 208 230V 50 60 HZ 1 3 PHASE TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 75: ...07610 003 61 42 T TEMPSTAR 208 230V 50 60 HZ 1 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES 68 ...
Страница 76: ...69 07610 003 61 42 T SCHEMATICS SOLID STATE 460 V 60 HZ 3 PHASE TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 77: ...70 TEMPSTAR 460 V 60 HZ 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 79: ...72 TEMPSTAR LT NB 208 230V 50 60HZ 1 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 80: ...73 07610 003 61 42 T SCHEMATICS TEMPSTAR NB LT 460V 50 60 HZ 3 PHASE TOP MOUNT UNIVERSAL TIMER ...
Страница 82: ...75 07610 003 61 42 T SCHEMATICS SDI OPTIONS ...
Страница 83: ...76 07610 003 61 42 T DRAIN QUENCH OPTIONS SCHEMATICS ...
Страница 85: ......