07610-003-61-42-T
ELECTRICAL REQUIREMENTS
SPECIFICATIONS
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical
fi xed-trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection
than what is displayed here. Always verify with your electrical service contractor that your circuit protection is
adequate and meets all applicable national and local codes. These numbers are provided in this manual simply for
reference and may change without notice at any given time.
VOLTS
PHASE
HZ
RINSE HEATER
RATINGS
TOTAL
AMPS
TYPICAL
ELECTRICAL CIRCUIT
208
1
50
12KW@240V
71 A
90 AMP
208
1
50
14KW@240V
78 A
100 AMP
230
1
50
12KW@240V
78 A
100 AMP
230
1
50
14KW@240V
86 A
110 AMP
TEMPSTAR Electrical Characteristics:
208
3
50
12KW@240V
45 A
60 AMP
208
3
50
14KW@240V
49 A
70 AMP
230
3
50
12KW@240V
48 A
60 AMP
230
3
50
14KW@240V
53 A
70 AMP
380
3
50
12KW@380V
29A
40 AMP
380*
3
50
14KW@208V
34A
45 AMP
415
3
50
12KW@415V
26 A
35 AMP
415
3
50
14KW@415V
29 A
40 AMP
440
3
50
12KW@460V
21 A
30 AMP
440
3
50
14KW@460V
25 A
35 AMP
208
1
60
12KW@240V
69 A
90 AMP
208
1
60
14KW@240V
76 A
100 AMP
230
1
60
12KW@240V
76 A
100AMP
230
1
60
14KW@240V
84 A
110 AMP
208
3
60
12KW@240V
43 A
60 AMP
208
3
60
14KW@240V
47 A
60 AMP
230
3
60
12KW@240V
46 A
60 AMP
230
3
60
14KW@240V
51 A
70 AMP
460
3
60
12KW@480V
22 A
30 AMP
460
3
60
14KW@480V
25 A
35 AMP
6
* This model is wired in a wye confi guration for the heaters.
Содержание TEMPSTAR
Страница 2: ......
Страница 31: ...24 07610 003 61 42 T TOP CONTROL BOX ASSEMBLY PARTS Continued 26 1 29 28 30 33 34 36 ...
Страница 66: ...59 07610 003 61 42 T PARTS TEMPSTAR VENTLESS SYSTEM ASSEMBLY ...
Страница 74: ...07610 003 61 42 T 67 SCHEMATICS SOLID STATE 208 230V 50 60 HZ 1 3 PHASE TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 75: ...07610 003 61 42 T TEMPSTAR 208 230V 50 60 HZ 1 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES 68 ...
Страница 76: ...69 07610 003 61 42 T SCHEMATICS SOLID STATE 460 V 60 HZ 3 PHASE TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 77: ...70 TEMPSTAR 460 V 60 HZ 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 79: ...72 TEMPSTAR LT NB 208 230V 50 60HZ 1 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 80: ...73 07610 003 61 42 T SCHEMATICS TEMPSTAR NB LT 460V 50 60 HZ 3 PHASE TOP MOUNT UNIVERSAL TIMER ...
Страница 82: ...75 07610 003 61 42 T SCHEMATICS SDI OPTIONS ...
Страница 83: ...76 07610 003 61 42 T DRAIN QUENCH OPTIONS SCHEMATICS ...
Страница 85: ......