07610-003-61-42-T
Model Designation:
TEMPSTAR
PERFORMANCE/CAPABILITIES
Operating Capacity:
High Temperature
Racks per Hour
58
Dishes per Hour
1450
Glasses per Hour
1450
Low Temperature
Racks per Hour
50
Dishes per Hour
1250
Glasses per Hour
1250
Operating Cycle (SECONDS):
Minimum (other cycle times are available)
High Temperature
Wash Time
40
Rinse Time
13
Dwell Time
4
Total Cycle Time
57
High Temperature Ventless
Wash Time
40
Rinse Time
13
Dwell Time
4
Condensate Removal
30
Total Cycle Time
87
Low Temperature
Wash Time
45
Rinse Time
11
Dwell Time
10
Total Cycle Time
66
Tank Capacity (Gallons):
Wash Tank
8.0
Rinse Tank (TEMPSTAR)
3.0
Tank Capacity (Liters):
Wash Tank
30.3
Rinse Tank (TEMPSTAR)
11.4
Steam Requirements:
Coil Size
3/4"
Steam Flow Pressure (P.S.I)
10-20
Consumption @ 15 P.S.I. ( Lbs/Hr)
45
OPERATING CAPACITIES
SPECIFICATIONS
Electrical Loads (as applicable):
Wash Motor HP
3/4
Wash Heater KW
4
Rinse Heater KW
4
WATER REQUIREMENTS
TEMPSTAR & VENTLESS:
Wash Temperature (Minimum)(°F)
150
Wash Temperature (Minimum)(°C)
66
Rinse Temperature (Minimum)(°F)
180
Rinse Temperature (Minimum)(°C)
83
Inlet Water Temperature:
12KW Rinse Heater (°F)
140
12KW Rinse Heater (°C)
60
14KW Rinse Heater (°F)
110
14KW Rinse Heater (°C)
44
Ventless
(°F)
40-70
Ventless
(°C)
4.4-21
Flow Pressure (PSI)
10
Water Line Size (NPT) (Vented)
1/2”
Water Linse Sze (Ventless)
3/4"
Drain Line Size (NPT)
1 1/2”
TEMPSTAR LT:
Wash Temperature (Minimum)(°F)
130
Wash Temperature (Minimum)(°C)
55
Rinse Temperature (Minimum)(°F)
130
Rinse Temperature (Minimum)(°C)
55
Inlet Water Temperature (°F)
130
Inlet Water Temperature (°C)
55
Flow Pressure (PSI)
10
Water Line Size (NPT)
1/2”
Drain Line Size (NPT)
1 1/2”
Minimum Chlorine Required (PPM)
50
TEMPSTAR NB/ TEMPSTAR S:
Wash Temperature (Minimum)(°F)
150
Wash Temperature (Minimum)(°C)
66
Rinse Temperature (Minimum)(°F)
180
Rinse Temperature (Minimum)(°C)
83
Inlet Water Temperature (°F)
180
Inlet Water Temperature (°C)
83
Flow Pressure (PSI)
10
Water Line Size (NPT)
1/2”
Drain Line Size (NPT)
1 1/2”
NOTE: Always refer to the machine data plate for specifi c electrical and water requirements.
The material provided on this page is for reference only and is subject to change without notice.
5
Содержание TEMPSTAR
Страница 2: ......
Страница 31: ...24 07610 003 61 42 T TOP CONTROL BOX ASSEMBLY PARTS Continued 26 1 29 28 30 33 34 36 ...
Страница 66: ...59 07610 003 61 42 T PARTS TEMPSTAR VENTLESS SYSTEM ASSEMBLY ...
Страница 74: ...07610 003 61 42 T 67 SCHEMATICS SOLID STATE 208 230V 50 60 HZ 1 3 PHASE TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 75: ...07610 003 61 42 T TEMPSTAR 208 230V 50 60 HZ 1 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES 68 ...
Страница 76: ...69 07610 003 61 42 T SCHEMATICS SOLID STATE 460 V 60 HZ 3 PHASE TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 77: ...70 TEMPSTAR 460 V 60 HZ 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 79: ...72 TEMPSTAR LT NB 208 230V 50 60HZ 1 3 PHASE SCHEMATICS TEMPSTAR TOP MOUNT W CYCLE SWITCHES ...
Страница 80: ...73 07610 003 61 42 T SCHEMATICS TEMPSTAR NB LT 460V 50 60 HZ 3 PHASE TOP MOUNT UNIVERSAL TIMER ...
Страница 82: ...75 07610 003 61 42 T SCHEMATICS SDI OPTIONS ...
Страница 83: ...76 07610 003 61 42 T DRAIN QUENCH OPTIONS SCHEMATICS ...
Страница 85: ......