background image

Installation manual: Oasis security system JA-80K  

- 18 - 

 MKE51801

 

 

MM

  

is the month (01 to 12) 

YY

  

is the year (00 to 99) 

 

Note

: The internal clock can also be adjusted in maintenance mode.  

 
Example:

 On 30 June 2012 at 17:15 enter:  

4 17 15 30 06 12 

 

After the control panel is powered up, the clock is set to  00 00 01 01 00. 

 

12.47.  Editing keypad text 

 

The names of devices and programmable outputs as displayed 
on the keypad unit can be edited as follows:  

  Pressing and holding the 

?

 key (in service mode) enters text 

editing mode and the name of the device enrolled to address 
01 is then displayed with a flashing cursor on the first text 
character. 

 Key functions: 

 and   text scrolling (see table)  

 1

 and 

7  

character-selection 

(A,B,C,D.......8,9,0) 

4

 and 

cursor control (left/right) 

2

 

delete selected character 

exit editing (& save changes) 

 

 
 
 
List of editable text: 

text  

Description 

01: to 50: Devices 

Names of devices in addresses 01 to 50 

Control panel 

Name of control panel (e.g. displayed if its cover 
is opened) 

Keypad 

Name of hard-wired keypad 

Communicator 

Name of the communicator in the control panel 

Master code 

Name of the master code 

01: to 50: Code 

Names of user codes  

ARC Code 

Names of ARC code 

Service code 

Name of the service code 

PGX  and PGY 

Names of programmable outputs 

OASIS JA-80 

The default text displayed in operating mode if 
no other text needs to be displayed. If erased 
then nothing will be displayed. 

 

Notes: 

  Only capital letters can be entered. 

  The length of text is limited to the length of the display. 

 The text is only stored in the keypad used for editing (different 

keypads in the system can show different text if desired). 

 Text is stored in the non-volatile memory of keypads, so power 

disconnection will not erase any stored text. 

 Convenient text editing is possible using a PC running Comlink 

software. 

  Besides device names, keypads also use so-called internal text such 

as “service”, “maintenance mode” etc, and this text can also be edited 
via Comlink software by selecting “Settings” on the menu and then 
“keypad text”.  

 After editing keypad text using Comlink software, all keypads 

(including wireless ones) must be connected to the digital bus to save 
the changes to the keypad units by clicking on the OK button in the 
software. 

 

Factory default setting:

 in addresses 01 to 50 there is the text 

“Device”. Other default text: “Control panel”, “Keypad”, 
“Communicator”, “Master code”, users 01 to 50 “Code”,”ARC 
Code”, “Service code”, “PGX”, “PGY” and “OASIS JA-80”. 
 

13. Operating the system 

 

The Oasis system can be operated locally using a keypad or 

a keyfob and it can also be operated remotely by mobile phone 
or the Internet (if equipped with a suitable communicator). 

 

13.1. 

The system keypad 

Indoor keypads model JA-80F (wireless) or JA-80E (wired) can 
be used to operate and program the system. Both keypad types 
provide the same functionality: 

 

 

13.1.1. Keypad 

indicators: 

ABC  setting (arming) status of sections 

– if all sections are 

set then all these indicators (A B & C) are lit. 

 

 

flashing = alarm, 

with the simultaneous display of alarm 

details on the LCD, e.g.:  
   

Alarm  

03: Kitchen

 

constantly lit = fault

 – details are displayed by pressing 

the “

?

” key  

 

 

power

. Constantly lit = mains ok. Flashing = no mains, 

control panel powered by back-up battery only.

 

 

13.1.2. LCD 

display 

The 1

st

 line displays the status: 

triggered detector, Service 

mode etc. In standby mode, it shows the text “OASIS JA-80” 
(editable, see 12.47). 

The 2

nd

 line displays the name of a device.

(e.g. 01: Main Door 

etc.). The text can be edited, see 12.47. 

 

Displaying the status of detectors and programmable 
outputs:

  Details on permanently triggered detectors (e.g. open 

windows) and the status of the PGX and PGY outputs can be 
displayed by pressing the 

key. 

 

13.1.3. Keypad 

display 

sleep-mode 

In operating mode, the wireless keypad unit displays the 

system status for 20 seconds (if battery-powered) after the last 
interaction with a user, and then goes into sleep mode. Pressing 
any key, triggering the keypad input or opening the keypad’s flip 
cover re-activates the display.  

 

13.1.4. Keys 

 

0–9

  digital code entry 

  

function sequences 

#

  

escape 

ABC

  hot key for setting the entire system (all sections A, B & 

C)  

A

 

hot key for setting section A (e.g. afternoon partial setting 
of the garage)  

Содержание Oasis JA-80

Страница 1: ...trol panel installation manual This manual is valid for control panel JA 80K version KE60108 printed on internal circuit board The control panel can be configured by a PC running ComLink software vers...

Страница 2: ...WIRELESS SIREN ALARM ENABLED IW AND EW 13 12 22 AUTO BYPASS USER APPROVAL VIA THE KEY 13 12 23 FINAL DOOR DETECTORS 13 12 24 PARTIAL SETTING ARMING OR SYSTEM SPLITTING 14 12 25 AUTOMATIC SUMMER TIME D...

Страница 3: ...two inputs are not used the two addresses can be used to enroll wireless devices Hard wired inputs are also provided by some wireless devices such as keypads door detectors and PIR movement detectors...

Страница 4: ...e T 200 mA The control panel power supply is double insulated safety class 2 and does not incorporate a protective earth wire A double insulated power cable should be used with a minimum cross section...

Страница 5: ...ered and an external warning will only follow if the entrance delay has been exceeded PGX PGY are a pair of terminals providing programmable outputs If an output is activated it switches to GND with a...

Страница 6: ...r a while before pressing and holding the key the language can be selected for each individual keypad in the system i e different keypads can display different languages for example if foreigners are...

Страница 7: ...siren can be activated by pressing its button A JA 80A outdoor siren can be activated for signal strength measurement by opening its cover thereby triggering its cover tamper switch Each installed dev...

Страница 8: ...min 4 min 0 10s for testing PGX function 23x 7 on off 80 81 PGY function 24x x in an unsplit system 0 whole system set ABC PG on 1 any system part set PG on 2 AB set not C PG on 3 Fire alarm PG on 4 P...

Страница 9: ...O NO Changes internal clock 1h on Apr 1 1h on Nov 1 Tamper signal differential indication Tamper alarm in response to an increase in the number of triggered tamper sensors 681x 6811 ignore permanently...

Страница 10: ...nsplit then ABC hh hours mm minutes No action The scheduled actions will happen every day Changing the service code 5 NC NC NC new code 4 digits 8080 enter NC twice Go to maintenance mode 292 switches...

Страница 11: ...led 2 6 0 disabled Factory default setting disabled Note In some places the system can be permanently or occasionally affected by radio interference e g by nearby radar stations TV transmitters etc In...

Страница 12: ...ors 3 1 1 indication enabled 3 1 0 indication disabled Factory default setting indication enabled 12 15 Confirmation of intruder alarms To reduce the risk of false alarms and to comply with British st...

Страница 13: ...l i e setting by keyfob does not trigger an approval request The automatic bypass of a detector will end after the detector has been de triggered for example if a door is closed If auto bypass user ap...

Страница 14: ...es as two independent systems one being section A and the other section B There is also a common section C which is only set if section A and section B are set at the same time and is commonly used fo...

Страница 15: ...eceive a notification earlier than a year later change the internal clock settings to the day and month you prefer before exiting Service Mode by entering 4hhmmDDMMYY and then re adjust the clock to t...

Страница 16: ...ing the B key on the keypad e g setting arming the garage and the ground floor during the night ABC using the ABC key on the keypad e g to set the entire system when leaving the house In a split syste...

Страница 17: ...n be enrolled instead If a device with production code xx x has already been enrolled to another address in the past and if the device is now enrolled to a new address then it will be moved to the new...

Страница 18: ...the menu and then keypad text After editing keypad text using Comlink software all keypads including wireless ones must be connected to the digital bus to save the changes to the keypad units by clic...

Страница 19: ...ard then it is possible to program whether both a code and card must be presented to the system for system access or whether only one of them is required see 12 37 The system does not allow the same c...

Страница 20: ...mode as follows 1 The control panel must be in maintenance mode if not then enter 0 master code or card factory default 1234 while the system is totally unset 2 Press key 5 the display indicates Codes...

Страница 21: ...register at www GSMLink cz 15 Basic guidance for installers 1 Create an installation plan that sufficiently covers the building to be protected 2 If the customer requests changes to the suggested conf...

Страница 22: ...d and reports to the control panel Alternatively power the keypad with an AC adaptor to prevent sleep mode or install an indoor wireless siren type JA 80L to generate entrance delay beeps 17 Control p...

Отзывы: