background image

User manual JA-60GSM 

- 6 - 

MFJ51808

 

 

 

 

 

- 6 - 

MFJ51006  

 

 

 

3. 

73 ____ F0 

- ALARM SMS 
- ALARM CALL (audible warning)  

 

4. 

74 ____ F0 

 

5. 

75 ____ F0 

Any ALARM, ARMING & DISARMING SMS.

 

 

- ALARM CALL (audible warning)

 

- Technical

 

SMS

 

 

6. 

76 ____ F0 

 

7. 

77 ____ F0 

- ALARM CALL (audible warning)

 

 

8. 

 

Technical  SMS

  about  events  in  the  system.  This  position  is 

reserved for service organization. 

 

 

 

3.  Customization of SMS and audible warnings 

 

  The dialer can report all possible events of the alarm system via SMS (see table 3.2.1.).  

  There  are  factory  default  SMS  texts  available  for  all  possible  events  and  for  all  possible 

sources of the events. All texts can be edited. 

  It is possible to set which events will be reported to which telephone number. 

  It is possible to set which events should activate audible warnings. 

  It is possible to change incoming SMS command texts, which are used for remote controlling of 

the system. 

The  control  panel  must  be  in  the  user  mode  (see  section  2)  to  be  able  to  use  the  following 

programming sequences: 

3.1.  Events to be reported by SMS 

Table 3.2.1 shows the complete list of all possible events in the alarm system. It also shows which 

events  are  assigned  to  which  telephone  numbers  to  be  reported  via  SMS.  You  can  make  your  own 
setting by: 

 

81 uu t y 

where: 

uu  

is an event index from  01 to 31

 

t  

is a telephone number memory from1 to 7

 

y  

0

 = reporting disabled, 

= reporting enabled 

 

Example:

 

if you enter 810371 and a Fire alarm is triggered (event index 03) by detector number 1, the 

following  message  will  be  sent  to  the  7th  telephone  number:  “Alarm  system  reports:  Fire  alarm 
Wireless detector #1 Time: 16.04.  11:16”

 

Note: 

SMS reports consist of 4 text parts (installation name, event name, source name and time) 

– all 

of these texts can be edited, see section 3.3 for details.

 

3.2.  Assignment of audible warnings to be reported  

Table 3.2.1 also shows the complete list of all possible events in the alarm system. It shows which 

events  are  assigned  to  which  telephone  numbers  to  be  audibly  reported.  You  can  make  your  own 
setting by: 

 

82 uu t y 

where: 

uu  

is an event index from 01 to 31

 

t  

is a telephone number memory from1 to 7

 

y

  

= reporting disabled, 

= reporting enabled

Содержание JA-60GSM

Страница 1: ......

Страница 2: ...uctions sent via SMS or by dialing in and operating the system via the phone keypad which operates in the same way as the alarm system keypad The dialing in method can also be preformed from an ordinary landline telephone The following description matches the factory default settings of the dialer The described features can be modified during the installation The installer should explain clearly a...

Страница 3: ...r if AM or DM is used it will arm if the system is disarmed and it will disarm if the system is armed 1 7 Mode request via SMS MO Command MO can be used to read the current alarm system mode The dialer will reply with a reporting SMS to the phone which sent the MO command about status level of GSM signal GPRS status successfulness of transferring date to the CMSs Send SMS text to the dialer MO Exa...

Страница 4: ...a short beep c Enter the remote user access code factory default setting is 1111 to change this code see section 4 1 d The system will confirm the validity of the code with a beep e From this moment you can operate the PgX and PgY outputs by entering 80 to switch off 81 to switch on permanently f To terminate the connection simply hang up Connection will automatically terminate if there is no entr...

Страница 5: ...g see table 2 2 By entering a telephone number to a particular memory selects what will be reported to this number 7t xxx x F0 where t is a memory from 1 to 7 xxx x is a telephone number max 20 digits enter F9 before the number if you need prefix for international calls To use an attached SMS phone set enter code 001 instead of the telephone number To disable reporting to a particular number delet...

Страница 6: ...sequences 3 1 Events to be reported by SMS Table 3 2 1 shows the complete list of all possible events in the alarm system It also shows which events are assigned to which telephone numbers to be reported via SMS You can make your own setting by 81 uu t y where uu is an event index from 01 to 31 t is a telephone number memory from1 to 7 y 0 reporting disabled 1 reporting enabled Example if you ente...

Страница 7: ...User manual JA 60GSM 7 MFJ51808 3 2 1 Table SMS reports assignments to telephone numbers ...

Страница 8: ...ncle Sam s controller 202 aunt Mary s controller to the dialer will change names of remote controllers No 1 and 2 3 3 1 Table of SMS texts Text index z Factory default text Text index z Factory default text 110 Master code 301 Wired detector 1 201 Controller 1 302 Wired detector 2 202 Controller 2 303 Wired detector 3 203 Controller 3 304 Wired detector 4 204 Controller 4 305 Wired detector 5 205 ...

Страница 9: ... best location for the antenna while measuring the signal level To switch the system back to the user mode press the N key 4 4 Attached phone function The dialer provides a PHONE output to connect an ordinary telephone set The function of this telephone can be modified by entering 98 y where function y 0 ordinary telephone line is simulated it is possible to make phone calls indicated by a dial to...

Страница 10: ...ommand SMS 1111 PRG F61234 02 6789 After receiving this command message the new user code 6789 will be added into the control panel 4 7 Prepaid SIM cards The JA 60GSM communicator can send information about the credit of a prepaid SIM card An SMS sent from any of the stored numbers sequence 7t containing the word CREDIT followed by the correct instruction different for every provider will result i...

Страница 11: ... transferred back to the server 5 4 Reading of history events History events are readable in any state of the control panel service code is not needed One SMS contains 20 events If it is necessary to read all of the events the GSM dialer will send 7 SMS messages 6 The Modem function The GSM communicator can also be used as an external modem for accessing the Internet GPRS format It is necessary to...

Страница 12: ......

Отзывы: