background image

User manual JA-60GSM 

- 8 - 

MFJ51808

 

 

 

 

 

- 8 - 

MFJ51006  

 

 

 

 

 

 

 

- 8 - 

MFJ51006  

 

 

 

3.3.  SMS texts editing 

The  list  of  SMS  texts  stored  in  the  dialer  consists  of  texts  reported  as  event  reports  (installation 

name, event name and source name) and texts for remote control instructions. All these texts can be 
edited by the following SMS sent from a mobile phone. 

 

yyyyy

TXT

z,text, z,text 

where: 

yyyyy

 

is the  remote  access code;  default setting  is  1111; this code can  be  changed, 
see section 4.1 

TXT 

is the text programming command 

is the text index (110 - 711 see table 3.3.1).   

,  

comma (separator)

 

text 

is the new text string. Neither a comma nor a dot can be used inside the text. Space 
inside the text is a valid character (dialer ignores spaces out of the “text” string) 

 

separator (asterisk or space)

 

Note:

 

If  you  change  texts  of  command  SMS  this  way  (texts  no.  703  to  711),  then  you  will  actually 

change  the  commands  which  the  system  reacts  to.  E.g.:  if  you  change  text  „MO“  (text  no.  705)  to 
„STATE OF THE ALARM SYSTEM?“ then this command can only be used to learn the status of the 
system.  You  can  change  texts  for  your  needs  and  also  insert  a  password  to  protect  against 
unauthorized use of SMS commands. 

Example:

 If  the factory default code for the dialer is 1111, then the sending of SMS: 

1111*TXT*201, uncle Sam’s controller, 202, aunt Mary’s controller 

to the dialer will change names of remote 

controllers No. 1 and 2. 

3.3.1. 

Table of SMS texts 

 

Text index z 

Factory default text 

Text index z 

Factory default text 

110 

Master code 

301 

Wired detector #1 

201 

Controller #1 

302 

Wired detector #2 

202 

Controller #2 

303 

Wired detector #3 

203 

Controller #3 

304 

Wired detector #4 

204 

Controller #4 

305 

Wired detector #5 

205 

Controller #5 

306 

Wired detector #6 

206 

Controller #6 

307 

Wired detector #7 

207 

Controller #7 

308 

Wired detector #8 

208 

Controller #8 

309 

Wired detector #9 

501 

User code #1 

310 

Wired detector #10 

502 

User code #2 

311 

Wired detector #11 

503 

User code #3 

312 

Wired detector #12 

504 

User code #4 

313 

Wired detector #13 

505 

User code #5 

314 

Wired detector #14 

506 

User code #6 

315 

Wired detector #15 

507 

User code #7 

316 

Wired detector #16 

508 

User code #8 

401 

Wireless detector #1 

509 

User code #9 

402 

Wireless detector #2 

510 

User code #10 

403 

Wireless detector #3 

511 

User code #11 

404 

Wireless detector #4 

512 

User code #12 

405 

Wireless detector #5 

513 

User code #13 

406 

Wireless detector #6 

514 

User code #14 

407 

Wireless detector #7 

700 

Alarm system reports: 

408 

Wireless detector #8 

703 

AM 

409 

Wireless detector #9 

704 

DM 

410 

Wireless detector #10 

705 

MO 

411 

Wireless detector #11 

706 

ME 

412 

Wireless detector #12 

707 

AUXON 

413 

Wireless detector #13 

708 

AUXOFF 

414 

Wireless detector #14 

710 

PGON 

415 

Wireless detector #15 

711 

PGOFF 

416 

Wireless detector #16 

 

Содержание JA-60GSM

Страница 1: ......

Страница 2: ...uctions sent via SMS or by dialing in and operating the system via the phone keypad which operates in the same way as the alarm system keypad The dialing in method can also be preformed from an ordinary landline telephone The following description matches the factory default settings of the dialer The described features can be modified during the installation The installer should explain clearly a...

Страница 3: ...r if AM or DM is used it will arm if the system is disarmed and it will disarm if the system is armed 1 7 Mode request via SMS MO Command MO can be used to read the current alarm system mode The dialer will reply with a reporting SMS to the phone which sent the MO command about status level of GSM signal GPRS status successfulness of transferring date to the CMSs Send SMS text to the dialer MO Exa...

Страница 4: ...a short beep c Enter the remote user access code factory default setting is 1111 to change this code see section 4 1 d The system will confirm the validity of the code with a beep e From this moment you can operate the PgX and PgY outputs by entering 80 to switch off 81 to switch on permanently f To terminate the connection simply hang up Connection will automatically terminate if there is no entr...

Страница 5: ...g see table 2 2 By entering a telephone number to a particular memory selects what will be reported to this number 7t xxx x F0 where t is a memory from 1 to 7 xxx x is a telephone number max 20 digits enter F9 before the number if you need prefix for international calls To use an attached SMS phone set enter code 001 instead of the telephone number To disable reporting to a particular number delet...

Страница 6: ...sequences 3 1 Events to be reported by SMS Table 3 2 1 shows the complete list of all possible events in the alarm system It also shows which events are assigned to which telephone numbers to be reported via SMS You can make your own setting by 81 uu t y where uu is an event index from 01 to 31 t is a telephone number memory from1 to 7 y 0 reporting disabled 1 reporting enabled Example if you ente...

Страница 7: ...User manual JA 60GSM 7 MFJ51808 3 2 1 Table SMS reports assignments to telephone numbers ...

Страница 8: ...ncle Sam s controller 202 aunt Mary s controller to the dialer will change names of remote controllers No 1 and 2 3 3 1 Table of SMS texts Text index z Factory default text Text index z Factory default text 110 Master code 301 Wired detector 1 201 Controller 1 302 Wired detector 2 202 Controller 2 303 Wired detector 3 203 Controller 3 304 Wired detector 4 204 Controller 4 305 Wired detector 5 205 ...

Страница 9: ... best location for the antenna while measuring the signal level To switch the system back to the user mode press the N key 4 4 Attached phone function The dialer provides a PHONE output to connect an ordinary telephone set The function of this telephone can be modified by entering 98 y where function y 0 ordinary telephone line is simulated it is possible to make phone calls indicated by a dial to...

Страница 10: ...ommand SMS 1111 PRG F61234 02 6789 After receiving this command message the new user code 6789 will be added into the control panel 4 7 Prepaid SIM cards The JA 60GSM communicator can send information about the credit of a prepaid SIM card An SMS sent from any of the stored numbers sequence 7t containing the word CREDIT followed by the correct instruction different for every provider will result i...

Страница 11: ... transferred back to the server 5 4 Reading of history events History events are readable in any state of the control panel service code is not needed One SMS contains 20 events If it is necessary to read all of the events the GSM dialer will send 7 SMS messages 6 The Modem function The GSM communicator can also be used as an external modem for accessing the Internet GPRS format It is necessary to...

Страница 12: ......

Отзывы: