User manual JA-60GSM
- 5 -
MFJ51808
- 5 -
MFJ51006
2. SMS and audible alarm reports setting
The factory default settings allow the GSM dialer to send SMS reports and audible warnings when the
control panel generates important pertinent information (alarms, arming, etc.). It is only necessary to set the
telephone numbers to where the information should be reported. If you want to report additional or different
events than the factory default provides, see section 3.
The following information is for use by an alarm system administrator who knows the master code.
All settings can be programmed via a keypad. A sequence can be canceled anytime by pressing the
“N” key (e.g. entry error). When a sequence is complete, the system will store it into the memory. The
following settings are made in the
user mode, which can be entered by
:
F 0 master code
. (this mode is indicated by the “
U”
character on the keypad’s LED display).
Example:
If the master code is 1234 then enter:
F0 1234
Press
“N”
to
exit the user mode.
2.1. Telephone numbers setting
The dialer has 8 telephone number memories. Each memory has particular SMS reports assigned to
it and/or audible warnings according to the default setting
– see table 2.2. By entering a telephone
number to a particular memory selects what will be reported to this number:
7t xxx...x F0
where:
t
is a memory from 1 to 7
xxx...x
is a telephone number (max. 20 digits), enter F9 before the number, if you need
+ prefix for international calls. To use an attached SMS phone set enter code
001 instead of the telephone number
To disable reporting to a particular number,
delete this number from the memory by entering
:
7tF0
where:
t
is a memory from 1 to 7
Report testing:
If you wish to report any alarm, arming and disarming via an SMS followed by a notifying call and your
mobile phone number is 123456789, then enter 75123456789F0 (while the control panel is in the
programming mode).
Then exit the programming mode by pressing the N key. Now when you arm the system your mobile
phone will receive a reporting SMS.
Notes
:
For SMS transfers use only numbers of mobile phones or call centers that can transfer SMS
messages.
Audible warnings can be used on both GSM and landline networks.
The GSM dialer can report all event information from the alarm system via SMS and audible
warnings. The setting of reported events for all numbers can be changed
– see chapter 3.
2.2. Telephone numbers table
Memory
Entering
sequence
To this pair of numbers will be sent (factory default):
Telephone numbers
1.
71 ____ F0
- ALARM SMS
- Technical
SMS
2.
72 ____ F0
Содержание JA-60GSM
Страница 1: ......
Страница 7: ...User manual JA 60GSM 7 MFJ51808 3 2 1 Table SMS reports assignments to telephone numbers ...