![iWeld DYNAMIG 560 Скачать руководство пользователя страница 172](http://html1.mh-extra.com/html/iweld/dynamig-560/dynamig-560_user-manual_2098556172.webp)
EN
44
Step 6
Connecting the fast socket as the picture below.
Connect to the blue fast socket of
connection hose package
Connect to the red fast socket of
connection hose package
Step 7
Switch on the machine.
Step 8
Press the torch switch again to test the water
fl
ow cycle. The cooling liquid should
fl
ow normally.
If it is not working, please repeat the whole test steps above.
If it still doesn’t work, check the continuity of the water
fl
ow, or please ask to the Service Center.
• Gas Check
Step 1
Turn on the knob of the gas cylinder, and turn the gas
fl
ow adjusting knob in anticlockwise direction.
Step 2
Press the button "
" on the control panel of wire feeder to test the gas.
Step 3
Turn the gas
fl
ow adjusting knob and watch the gas meter until it meet the require value, Press the button "
" again, the gas stops.
Содержание DYNAMIG 560
Страница 1: ...CUTTING EDGE WELDING R HASZN LATI TMUTAT DYNAMIG 560 MIG MAG hegeszt g p...
Страница 65: ...CUTTING EDGE WELDING R BEDIENUNGSANLEITUNG DYNAMIG 560 MIG MAG Schwei ger t...
Страница 129: ...CUTTING EDGE WELDING R USER S MANUAL DYNAMIG 560 MIG MAG Welding Power Source...
Страница 195: ...HU EN 67...
Страница 196: ...www iweld hu...