![iWeld DYNAMIG 560 Скачать руководство пользователя страница 153](http://html1.mh-extra.com/html/iweld/dynamig-560/dynamig-560_user-manual_2098556153.webp)
HU
EN
25
2.6.17 JOB and PRG
Description for JOB
The staff can con
fi
gure the welding parameters and manage them by the JOB numbers. In the next welding pro-
cess, the JOB number can be selected directly, and the work ef
fi
ciency can be greatly improved without setting
up parameters. Please see the following table for parameter descriptions.
No.
Item
Range
Description
F02
Welding mode
1-4
1: manual welding mode,
2: synergic welding mode,
3: pulsed welding mode
4: double pulsed welding mode
F04
Up-slope time
0-5s
Only for 4S cycle When the welding mode (F02) is "1",
"2", "3" or "4", it is effective.
F05
Start current
60% -150%
Only for 4S cycle When the welding mode (F02) is "1",
"2", "3" or "4", it is effective.
F06
Arc start time
0-5s
Only for robot system When the welding mode (F02) is
"1", "2", "3" or "4", it is effective.
F07
Down-slope time
0-5 s
Set the down-slope time When the welding mode
(F02) is "1", "2", "3" or "4", it is effective.
F08
Stop current
20% -80%
Only for 4S cycle When the welding mode (F02) is "1",
"2", "3" or "4", it is effective.
F09
Arc stop time
0-5 s
Only for robot system When the welding mode (F02) is
"1", "2", "3" or "4", it is effective.
F010
Welding current
Min-max
Set the welding current When the welding mode (F02)
is "2", "3" or "4", it is effective.
F011
Arc length
-50 -+50
Set the arc length When the welding mode (F02) is "2",
"3" or "4", it is effective.
F012
Welding voltage
12.0V-40.0V/45V
The value depends from the size of the machine, 40V
for the DYNAMIG 560 then the welding mode (F02) is
"1", it is effective.
F013
Wire feeding speed
1.5-24.0 m/min
Set the motor speed of wire feeder When the welding
mode (F02) is "1", it is effective.
F014
Inductance
-50 -+50
Set the inductance modi
fi
cation When the welding
mode (F02) is "1", "2", "3" or "4", it is effective.
F015
BBT
-10 -+10
Set the BBT modi
fi
cation hen the welding mode (F02)
is "1", "2", "3" or "4", it is effective.
F016
Lift MIG
On/Off
"On" means the function is turned on. "Off" means the
function is off. When the welding mode (F02) is "3" or
"4", it is effective.
Содержание DYNAMIG 560
Страница 1: ...CUTTING EDGE WELDING R HASZN LATI TMUTAT DYNAMIG 560 MIG MAG hegeszt g p...
Страница 65: ...CUTTING EDGE WELDING R BEDIENUNGSANLEITUNG DYNAMIG 560 MIG MAG Schwei ger t...
Страница 129: ...CUTTING EDGE WELDING R USER S MANUAL DYNAMIG 560 MIG MAG Welding Power Source...
Страница 195: ...HU EN 67...
Страница 196: ...www iweld hu...