EN
26
No.
Item
Range
Description
F017
Pulse frequency
0.5-4.0
When the welding mode (F02) is "4", it is effective.
F018
Balance
20% -80%
When the welding mode (F02) is "4", it is effective.
F019
Level
30% -90%
When the welding mode (F02) is "4", it is effective.
F020
Welding time
0.1-25 s
Only for spot cycle
F021
Pre-gas time
0.1-5.0 s
Set the pre-gas time When the welding mode (F02) is
"1", "2", "3" or "4", it is effective.
F022
Hot start
0 -10
When the welding mode (F02) is "3" or "4", it is effec-
tive.
F050
JOB number
1-50
Selecting JOB to modify existing JOB, if you choose
the display will blink, if you want to do a new JOB
brought it to the last available, the only one that
doesn't blink.
The instructions for parameters up-slope time, start current, arc start time, down-slope time, stop current, arc stop
time, pre-gas time are shown in the following
fi
gure.