− 18 −
1. How to operate
①
Confirm if pump, solenoid valve, alarm devices and electro-pneumatic regulator are connected correctly each other,
and if it is connected DC24V as well.
(Adjust voltage to DC24V with the help of transformer if it is an abnormal voltage.)
②
Supply air to preliminary inlet of electro-pneumatic regulator with manual regulator.
2-1 Flow of setting
Flow of setting is as follow.
Setting Pump Sensor
Power on
No. 1
No. 2
No. 3
No. 4
No. 5
No. 6
No. 7
No. 8
No. 9
No. 10
No. 11
Selecting Timer
NO
Selecting Sensor
YES
No. 3
No. 8
No. 9
No. 10
No. 11
No. 2
NO
No. 12
No. 3
No. 9
No. 11
No. 3
No. 9
No. 11
No. 12
YES
Setting Electro-pneumatic
regulator presence
Setting 1 shot of pump
discharge
Setting necessary pump
discharge
Setting maximum air supply
pressure for Electro-pneumatic
regulator
Completion of setting
(Control of constant discharge)
Setting key protect for setting
operation
Setting standard No. of stroke
of detection
Setting standard No. of count
of detection for Life alarm
Setting standard time of
detection for Time up alarm
Setting air supply pressure
when pump starts
Setting minimum air supply
pressure for Electro-pneumatic
regulator
Setting 1 shot of pump
discharge
Setting standard time of
detection for Time up alarm
Setting standard count number
of detection for Life alarm
Setting standard stroke rate of
detection for First alarm
Setting key protect for setting
operation
Completion of setting
(Normal operation)
Setting Electro-pneumatic
regulator presence
No. 5
No. 6
No. 7
Setting maximum air supply
pressure for Electro-pneumatic
regulator
Setting air supply pressure
when pump starts
Setting minimum air supply
pressure for Electro-pneumatic
regulator
Setting Pump stroke rate
Setting 1 shot of pump
discharge
Setting standard count number
of detection for Life alarm
Setting key protect for setting
operation
Completion of setting
(Timer mode)
Setting Pump stroke rate
Setting 1 shot of pump
discharge
Setting standard count number
of detection for Life alarm
Setting key protect for setting
operation
Completion of setting
(Timer mode)
2. How to set controller