− 10 −
(1) Installation to instrument panels (see the illustration):
Fig. 4
• Cutout (W141 x H44mm) on instrument panel.
• Tap 4 screw holes (W148 x H38mm) for fitting.
• Insert the controller into the hole, and fix firmly with M4 screws.
• Install with enough room toward the depth.
PUMP CONTROLLER
MODEL
FDC-1
IWAKI
RUN
LEAK
TIME
LIFE
FAST
CN1
CN2
CN3
CN4 CN5 CN6
141
+1
0
148
±
0.3
4-
φ
4.5
4-
φ
4.5
44
+1 0
38
±0.3
136
152
158
SELECT
MENU
ENT
AUTO
MANU
148
38
48
42.3
(2)
1. Installation
WARNING
• Do not install or store at explosion atmosphere, such places causing particulate or corrosion
gases (such as chlorine gas).
It may cause fire or harm to human body.
2. Connection
Execute wiring and piping referring illustrations 5 & 6 of which shows electrical wiring of controller and piping
drawing of air and charts 2 ~ 7 as well as an instruction of pump.
Caution: In case of wrong wiring, it may cause breakdown or wrong operation of controller and
pump. Please pay special attention!