− 20 −
• Setting screen No.5 (Setting the maximum air pressure being supplied by Electro-pneumatic regulator)
5. E−P Reg Pres.
MAX.= 0.** MPa
• Setting the maximum air pressure being supplied by Electro-
pneumatic regulator in 0.** area.
• Input of value shall be processed as same as Setting screen No.3.
• Electro-pneumatic regulator supplies air as the setting value is to be
the upper limit.
• For the protection of pump, do not set the value exceeding the
maximum air pressure supply of pump.
• Setting screen No.6 (Setting the minimum air pressure being supplied by Electro-pneumatic regulator)
6. E−P Reg Pres.
MIN.= 0.** MPa
• Setting the minimum air pressure being supplied by Electro-
pneumatic regulator in 0.** area.
• Input of value shall be processed as same as Setting screen No.3.
• Electro-pneumatic regulator supplies air as the setting value must be
the lowest limit.
• Setting screen No.7 (Setting the air pressure being supplied at the start of pump operation)
7. START Pres.
sp= 0.** MPa
• Setting the required air pressure at the start of pump operation.
• Input of value shall be processed as same as Setting screen No.3.
• For the protection of pump, do not set the value exceeding the
maximum air pressure supply of pump.
• Setting screen No.8 (Setting the standard time of Time Up alarm detection)
8. TIME UP ALARM
T= **.* Sec
• Setting the standard time of Time Up alarm detection in **.* area.
• Input of value shall be processed as same as Setting screen No.3.
• In case pump operates slower than the setting value, then the alarm
will be output.
• Setting screen No.9 (Setting the standard count number of Life alarm detection)
9. LIFE ALARM
L= ****×100000 count
• Setting the standard count number of Life alarm detection in ****
area.
• Input of value shall be processed as same as Setting screen No.3.
• In case pump operates exceeding the setting value, then the alarm
will be output.
• Setting screen No.10 (Setting the standard stroke rate of Fast alarm detection)
10. FAST ALARM
F= ***.* spm
• Setting the standard count number of Fast alarm detection in ***.*
area.
• Input of value shall be processed as same as Setting screen No.3.
• In case pump operates faster than the setting value, then the alarm
will be output.
• Setting screen No.4 (Setting the required flow rate of pump)
4. FLOW RATE SET
f r=***.* L/min
• Setting the required flow rate of pump in ****.* area.
• Input of value shall be processed as same as Setting screen No.3.
• For the protection of pump, do not set the value exceeding the
maximum discharge capacity.