29
– Check the ingot or program selection
– Observe the “sprueing and investment guidelines” according to
the instructions for use of the material
– Check whether the investment ring was placed in the center or
whether the firing plate is clean or the size of the Alox plunger is
correct and the plunger clean
– Check the press plunger for cracks or correct fixation and whether
the firing plate is contaminated or fractured
– Otherwise, possible defect of the press drive – please contact your
local Ivoclar Vivadent Service Center.
6.4 Further possibilities and special features of the
furnace
6.4.1 Quick program selection
Each program can be directly
selected by its program number.
The program number is shown in
the upper left area of the program
display (e.g. P95). To quickly select
a program, press the P key and
enter the program number.
Confirm with the Enter key.
After pressing the P key, the
individual programs can be
additionally run through using the +/- keys.
6.4.2 Illogical values or incorrect entries
If an illogical value is entered by
means of the numeric keys
(outside the current value range),
the invalid entry still blinks after
confirmation.
As error message (entry error:
entry outside the value range), an
exclamation mark blinks in the
bottom line until the next value
is entered and successfully
confirmed or the process is aborted with ESC. The old, valid value
reappears. Please refer to the parameter details for the value range.
6.4.3 Program write protection
–
Individual program write-protection active
Activate/deactivate with the corresponding touch button in the
parameter list and the +/- keys.
–
Individual group write-protection active
Change to page 2/2 in the „Settings“ screen using the + key.
Then, select „Extended settings“, followed by „Group write-
protection“. An individual group write-protection can be activated
using a random code and deactivated with the same code.
–
General write-protection active
Change to page 2/2 in the „Settings“ screen using the + key.
Then, select „Extended settings“, followed by „General write-
protection“. The general write-protection can only be activated or
deactivated with the user code. Each time the general write-
protection is deactivated, all the individual group write-protections
are also deactivated. The individual program write-protections,
however, will be maintained.
6.4.4 Stopping the running program
Press the STOP key once to pause a running program.The green LED
in the START key blinks. Press the STOP key twice to completely stop
the program or press START to continue.
6.4.5 Changing the parameters while the program is running
All parameters of the program, which have not yet been executed,
can be changed while the program is stopped (green LED blinks).
6.4.6 Standard / quick opening of the furnace head / CSP
The operator may select the furnace head opening mode by chang-
ing the symbol. The „minus“ or „plus“ keys can be used to toggle
back and forth:
–
“Standard furnace head opening“ symbol visible
(the furnace head opens within 60 seconds at
the end of the program).
–
“Quick furnace head opening“ symbol visible
(furnace head opens within 18 seconds at the
end of the program).
–
If the „CSP“ symbol is visible, the Cooling Shock
Protection function (CSP) has been activated (see
Chapter 5.4.)
6.4.7 Help
Help text for the current screen
6.4.8 Error message
The error group symbol should
supply a first indication of the type
of error (entry error = exclamation
mark; technical error = fork
wrench; Note = „i“ symbol) with-
out the user having to consult the
Operating Instructions.
6.4.9 One-stage / two-stage programs
If the cursor is on the „one-stage program“ symbol, pressing the
– / + key results in the symbol to change to the „two-stage
program“ symbol. At the same time, the program was also changed
to become a „two-stage program“.
If the cursor is on the „two-stage program“ symbol, pressing the
– / + key results in the symbol to change to the „one-stage
program“ symbol. At the same time, the program was also changed
to become a „one-stage program“.
6.4.10 Program status indication
The current program status is indicated in the operating indicator
“firing curve”:
pre-drying, closing, pre-vacuum, firing, long-term cooling, opening
Furthermore, the operating status is displayed in the coloured firing
curve (see 6.1.3). If the program is stopped, this is indicated by the
display flashing “Pause”. If a program is prematurely aborted,
“Vacuum discharge” is flashing while the firing chamber is flooded.
The program status is shown by means of the coloured status bar in
the remaining time operating display (see 6.1.4).
6.4.11 Pre-drying (one-stage or two-stage program)
For a program with individually
activated pre-drying, the desired
“pre-drying temperature“ is set
after the program start with the
furnace head open (heating or
cooling). Once this temperature is
reached, pre-drying is carried out
during the „pre-drying holding
time“ Once the holding time has
elapsed, the furnace head is closed
within the desired closing time.
Содержание Programat EP 5000 G2
Страница 1: ...Operating Instructions Programat EP 5000 G2 Valid as of Software Version 6 0...
Страница 2: ...2...
Страница 5: ...5 40 38 56 34 6 10 35 51 7 1 2 3 9 5 8 55 23 33 36 58 20 63 52...
Страница 39: ...39 10 2 Menu structure 10 2 1 Possibilities of the program selection Firing programs Press programs...
Страница 40: ...40 10 2 3 Overview of program groups 10 2 2 Adjustments Information...
Страница 41: ......
Страница 42: ......
Страница 43: ......