Adjusting the power supply number is only necessary in systems with multiple power
supplies daisy chained to a Communication Module or monitoring device. Having
multiple power supplies with the same numbers connected to a Communication Module
or monitoring device is not permitted.
To adjust the power supply number, turn the unit on and wait for the LED self-test to
complete. The COMM light will briefly stay lit and the power supply number may be
adjusted at this time. Press and hold the Calibrate button until the power supply number
increments by one (5 second window). Subsequent presses of the Calibrate button will
increment the power supply numbers (5 second window). The Ion Power station number
will be displayed and the IQ Power™ / Performax IQ BPS address will “map” as shown
on the Power Supply Number Table. The incrementing “wraps around”. Stop pressing
the Calibrate button when the desired power supply numbers have been reached. Wait
5 seconds, the COMM light will go out and the Speed and Distance LEDs will flicker,
indicating the power supply numbers have been saved.
To reset the unit to its factory default power supply numbers (see Power Supply Number
Table), press and hold the Calibrate button while turning the unit on. Continue holding
down the Calibrate button while the Output indicators “count-up” and when the COMM
light starts flashing, then release the Calibrate button. When just the Speed and Distance
LED flicker, the default power supply numbers (address = ”1”, station number = ”30”)
are saved.
Static Bar Operation
A. Operation normally requires only occasional checking of the system indicators on the
power supply.
B. Anticipated changes in the system indicators include a reduction of output over time.
This may occur over several weeks and ultimately cause the “Clean Bar” indicator to
light. Regular maintenance will typically prevent activation of the indicator.
C. Unanticipated changes in the system indicators include activation of the Fault
indicator. This would indicate faulty condition of static bar, power supply or high
voltage connections. See Troubleshooting section.
Communication Module Operation (optional)
A. Move the communication module “Power” switch to the “On” (1) position. The
communication module will include a full instruction manual (5201059).
B. The Anybus® CompactCom module will be powered and communicating with the IQ
Power™ system.
C. The Anybus® CompactCom module typically has built-in indicator lights for power
and communication. A Simco-Ion software technical specification specific to the
Anybus® network interface chosen is supplied with the communication module. See
Anybus HMS Industrial Networks (www.anybus.com) for more information specific
to the Anybus® module.