17
IQ Power™ BPS
5201197 Rev. D
Connect other Power Supplies
(if used with communication module). IQ Power™
BPS power supplies can be connected together via a “data buss”. The data buss
allows one computer communication module to serve multiple power supplies and
feed the data from all power supplies into the network. A total of 10 power supplies
may be chained together on one data buss. Cables for the data buss must be IQ
Power 8-conductor modular cables with RJ-45 connectors wired “straight through”
(reference color: white, Figure 5b).
The modular cable plugs into either “PS COMM 1” connector on a power supply
and chains to the next power supply where it again plugs into either “PS COMM 1”
connector. See Power Supply to Power Supply Connections diagram.
If mulitple IQ Power BPS power supplies are connected together, each power
supply must be given a unique address. This is necessary to enable reliable digital
communication. The power supplies should each be given a unique address prior to
connection of the “data buss” (the chaining together of power supplies). See section
6.3 Power Supply Number (address) for details on re-addressing the power supplies.
E.
Connect AC Adapter
(make sure “POWER” switch on power supply is in the “OFF”
(0) position). Route low voltage wire clear of moving machine parts and protect it
from abrasion. Secure using nylon wire ties (not supplied). Do not over tighten.
Insert barrel connector into “POWER IN” connector on the power supply. Hand
tighten barrel connector nut to secure.
If a Communication Module is used it requires a separate AC adapter. Connect AC
adapter (make sure “POWER” switch on communication module is in the “OFF” (0)
position). Route low voltage wire clear of moving machine parts and protect it from
abrasion. Secure using nylon wire ties (not supplied). Do not over tighten. Insert
barrel connector into “POWER IN” connector on the communication module. Hand
tighten barrel connector nut to secure.
Connect line voltage to input side of AC adapter. The AC adapter is a universal input
type that accepts line voltage from 100 to 240 VAC 50/60Hz. The AC adapter line
voltage connector accepts a line cord with an IEC 320 connector (supplied). The
line cord also provides electrical ground to the AC adapter. Check electrical ground
integrity in the line voltage receptacle used for the AC adapter. This ground must not
be defeated.
F.
Connect Control Station
(if used). The Control Station can supply 24 VDC power
for up to six 10 Power static eliminator power supplies. Use the 2.13 meter [7 foot]
(black) modular cable supplied with unit. Longer cables (not supplied) are available.
Cables for the Control Station must be IQ Power 8- conductor modular cables with
RJ-4S connectors wired “crossover” (reference color: black, Figure 5a).
The modular cable plugs into one of the six connectors numbered 5 thru 10, labeled
“POWER & COMM” on the Control Station and into either “PS COMM 1”
connector on the BPS power supply.