6. MAINTENANCE
NOTE
– Only qualified service personnel are to perform maintenance tasks.
CAUTION – Electrical Shock Hazard
Turn off power supply before cleaning bar or performing any maintenance
on the system.
ATTENTION – Risque De Choc Électrique
Coupez l’alimentation électrique avant de nettoyer la barre ou d’effectuer
un entretien sur le système.
The accumulation of contamination on ionization emitter points and static bar
surfaces will reduce neutralizing efficiency of the bar, therefore it is recommended
that maintenance of the system be performed when the Clean Bar indicator on
the Control Station illuminates or every three weeks, whichever comes first.
Dirty environments may require more frequent cleaning. Maintenance should be
performed by qualified service personnel only.
Cleaning the Static Bar
A clean brush with nylon bristles should be used to keep the ionization emitter
points of static bar clean. Periodic use of the brush will prevent deposits from
accumulating on the points. The emitter points must remain sharp for optimum
operation.
NOTE
– Do not scrape points with any hard or sharp object that may
damage points.
A. Turn off power supply.
B. Remove dirt particles deposited on static bar with a dry, stiff nylon bristle brush.
C. Blow off static bar with clean, dry compressed air.
D. Remove resistant coatings deposited on static bar by wiping with isopropyl
alcohol or mineral spirits applied to a clean cloth. Apply isopropyl alcohol or
mineral spirits to a stiff nylon bristle brush and thoroughly scrub the ionization
emitter channels of the bar.
E. Blow static bar dry with clean, dry compressed air and ensure the bar is
completely dry before re-applying power to bar.
NOTE
– Do not soak static bar or related components in alcohol or mineral
spirits. Do not use harsh solvents such as lacquer thinner, naphtha or
acetone.
Содержание SIMCO ION IQ Power HLC
Страница 2: ...5201259 Rev D IQ Power HLC Power Supply Control Station This page intentionally left blank ...
Страница 11: ...8 IQ Power HLC Power Supply Control Station 5201259 Rev D Figure 3a IQ Power HLC SPEED Control Drawing ...
Страница 12: ...9 IQ Power HLC Power Supply Control Station 5201259 Rev D Figure 3b IQ Power HLC HYBRID Control Drawing ...
Страница 23: ...20 IQ Power HLC Power Supply Control Station 5201259 Rev D Figure 10 IQ Power Connections Legacy Installations ...
Страница 35: ...32 IQ Power HLC Power Supply Control Station 5201259 Rev D This page intentionally left blank ...