19
IQ Power HLC Power Supply
& Control Station
5201259 Rev. D
G.
Connect User Supplied Power
(if used). In cases where the system does not
include a Control Station and the user wants to supply 24 VDC power to
the IQ Power HLC Power Supply directly, user supplied 24 VDC power may
be applied through the “Alarm Output” connector on end panel of the IQ
Power HLC power supply. This connector requires the use of a standard DB25
connector. The connector should be wired:
• +24 VDC to pins 13 & 25
• Common (ground) to pins 12 & 24
To ensure current carrying capacity, two pins are used for each connection. The
common must be bonded to ground.
Power supplied in above fashion must have adequate current available to power all
components on system (maximum 1.6A). Input power should be appropriately fused
for safety purposes.
In cases where a Control Station is not used, monitoring of operation through the
“Alarm Output” connector is recommended. See section E above.
H.
Connect Power to Remote Display Module (legacy installations).
Make sure
“POWER” switch on Remote Display Module is in “OFF” (0) position. Route
low voltage wire clear of moving machine parts and protect it from abrasion.
Secure using nylon wire ties (not supplied). Do not over tighten. Insert barrel
connector into “POWER IN” connector on Remote Display Module. Hand
tighten barrel connector nut to secure.
Connect line voltage to input side of AC adapter. The AC adapter is a universal
input type that accepts line voltage from 100 to 240 VAC 50/60 Hz. The AC
adapter line voltage connector accepts a line cord with an IEC 320 connector
(supplied). The line cord also provides electrical ground to the AC adapter.
Check electrical ground integrity in line voltage receptacle used for AC adapter.
This ground must not be defeated.
Содержание SIMCO ION IQ Power HLC
Страница 2: ...5201259 Rev D IQ Power HLC Power Supply Control Station This page intentionally left blank ...
Страница 11: ...8 IQ Power HLC Power Supply Control Station 5201259 Rev D Figure 3a IQ Power HLC SPEED Control Drawing ...
Страница 12: ...9 IQ Power HLC Power Supply Control Station 5201259 Rev D Figure 3b IQ Power HLC HYBRID Control Drawing ...
Страница 23: ...20 IQ Power HLC Power Supply Control Station 5201259 Rev D Figure 10 IQ Power Connections Legacy Installations ...
Страница 35: ...32 IQ Power HLC Power Supply Control Station 5201259 Rev D This page intentionally left blank ...