22
IQ Power HLC Power Supply
& Control Station
5201259 Rev. D
To manually adjust power supply address
, connect unit by itself to a Control
Station. Turn the Control Station on and allow the Control Station to begin
running. Tap the device icon for the HLC power supply. Tap the Neutralizer
tab. Tap the right arrow to get to page 2. Locate and tap the editing pencil icon
for Device Address. You will be prompted to enter the Control Station password
(default password is “password”). A touch pad will appear that may be used to
manually set the power supply address. Note: if a Sensor Interface is paired with the
power supply, but not connected to the power supply, its address will also have to
be changed manually by tapping the Sensor tab and tapping the right arrow to get
to page 4.
To automatically set power supply address of HLC
, use the Control Station. The
default Power Supply Number for a new unit is “1”. Plug first HLC system (only)
into Control Station and turn Control Station on. Allow Control Station to boot-
up and begin operation. Plug second system into Control Station. The Control
Station will re-address second HLC system to “2”. Plug third system into Control
Station. The Control Station will re-address third HLC system to “3”. Repeat this
process until all power supplies (or IQ Power / IQ Easy devices) are installed. Each
power supply or device will be given a unique address (device number).
Set Up (with IQ Power Control Station)
A variety of information can be checked, and operating parameters set, for the IQ
Power HLC power supply through the IQ Power Control Station via the device
page. Tap on device icon for the HLC power supply and static bar to access these
pages. A summary tab will appear offering important information. Tabs for the
neutralizer and sensor (if installed) will also appear. Tapping on a neutralizer tab
or sensor tab opens a page where operating parameters may be edited or selected.
Typical parameters are listed below.
Device Name
: A user editable name to identify specific device (14 character).
Bar Type
: A fixed description for the type of bar the HLC power supply is set for
(speed or hybrid).
Bar HV
: Allows turning internal HV power supplies on / off.
Ion Output
: Displays the ionization level, in percent, where Bar Calibration =
100% and the ionization level in terms of microamps for both positive and negative
ionization.
Balance
: A ratio of input power supplied to the high voltage power supplies that is
related to ion balance. In Fixed, Auto-Tune and CLFB modes this is a display only
and non-editable. The Balance may only be user adjusted in the Manual mode.
Operation Mode
: A user selectable operating mode for the static bar (Manual, Fixed,
Auto-Tune, CLFB).
Содержание SIMCO ION IQ Power HLC
Страница 2: ...5201259 Rev D IQ Power HLC Power Supply Control Station This page intentionally left blank ...
Страница 11: ...8 IQ Power HLC Power Supply Control Station 5201259 Rev D Figure 3a IQ Power HLC SPEED Control Drawing ...
Страница 12: ...9 IQ Power HLC Power Supply Control Station 5201259 Rev D Figure 3b IQ Power HLC HYBRID Control Drawing ...
Страница 23: ...20 IQ Power HLC Power Supply Control Station 5201259 Rev D Figure 10 IQ Power Connections Legacy Installations ...
Страница 35: ...32 IQ Power HLC Power Supply Control Station 5201259 Rev D This page intentionally left blank ...