Note that conduit seals must be properly installed to prevent the propagation of
vapors and flames through conduit runs. Outer (black) jacket of HV cables must
be removed and (white) insulated wires separated) before filling conduit seals with
cement. Use care not to nick or cut insulation on HV wires.
CAUTION – Electrical Shock Hazard
Do not connect static neutralizing bar with Power Supply energized.
Disconnect input power or switch power off before connecting static bar.
ATTENTION – Risque De Choc Électrique
Ne branchez pas la barre de neutralisation statique avec alimentation sous
tension. Couper l’alimentation ou coupez le courant avant de connecter la
barre statique.
NOTE
– Failure to fully seat high voltage connectors into power supply
connectors may result in permanent damage to bar, cable or power supply.