18
IQ Power HLC Power Supply
& Control Station
5201259 Rev. D
On the Remote Display Module (in legacy installations) there is a ribbon cable
connecting the face label on cover to the main circuit board. Use care not to
disconnect this cable. If cable becomes disconnected, lift the latches on sides
of ribbon cable connector, insert ribbon cable fully into connector and press
latches back down.
Reposition jumper to enable remote control either “normally on” or “normally
off”, as desired (see Figure 9). Then replace cover and secure with six screws.
When operating a Power Supply using the remote control circuit, power may
be applied through the “Alarm Output” connector or the “Power In” connector
on end panel. If the “Power In” connector on end panel is used, the “Power”
switch must be set to ON (1) position.
Remote control is established by applying 24V
DC to the “Alarm Output”
connector pins as specified in Figure 7. User-applied 24V
DC drives a low
current optoisolator on the main circuit board, turning Power Supply on or off,
depending on configuration of jumper J3.
Figure 8. Remote Control Optocoupler Schematic
Figure 9. Jumper Position at J3 for Remote Control Operation
Содержание SIMCO ION IQ Power HLC
Страница 2: ...5201259 Rev D IQ Power HLC Power Supply Control Station This page intentionally left blank ...
Страница 11: ...8 IQ Power HLC Power Supply Control Station 5201259 Rev D Figure 3a IQ Power HLC SPEED Control Drawing ...
Страница 12: ...9 IQ Power HLC Power Supply Control Station 5201259 Rev D Figure 3b IQ Power HLC HYBRID Control Drawing ...
Страница 23: ...20 IQ Power HLC Power Supply Control Station 5201259 Rev D Figure 10 IQ Power Connections Legacy Installations ...
Страница 35: ...32 IQ Power HLC Power Supply Control Station 5201259 Rev D This page intentionally left blank ...