16
5200860 Rev H
Ion-O-Vac
5. Resistant coatings may be removed with Isopropyl Alcohol (without additives)
applied with a clean cloth. Do not pour Isopropyl Alcohol on the bar or
soak the bar or any of its components in the alcohol. Do not use any other
commercial cleaners or solvents, or parts may be damaged. Dry thoroughly. Do
not attempt to scrape the points. The points must remain as sharp as possible
for optimum operation. If the points become dull or damaged, the bar must be
replaced. Let all alcohol evaporate completely before restoring power to the bar.
Flexible Tubing or Ducts
1. Ducting should be checked for blow-outs, punctures or other openings.
2. Check for any restrictions or dirt accumulation inside the ducting.
Collection System
This system incorporates an audible alarm which activates when the filter needs to
be cleaned or replaced. Make sure that the bypass air inlet (between the canister and
blower) is clean and open.
To clean the filter, blow from inside out with a high pressure air hose. The pre filter
may be washed out with mild soap and water.
8. TROUBLESHOOTING
Static Bar Operational Test
Equipment Needed: TenSION Voltage Detector (Part # 4050556)
WARNING! Fire Hazard
Remove intrinsically safe equipment (XP-2) from hazardous area or wait
until hazardous area clears of all volatile fumes before performing this
procedure.
CAUTION: High Voltage
- Refer testing to qualified personnel
1. Hold the TensION at a distance from the ionizing points / emitters. If a high
voltage is present, a red indicator in the plastic tip will illuminate.
a) If test produces no indication of voltage, perform static bar cleaning
procedure then check affected points for metal fragments. Repeat Steps 1
of the static bar operational test after performing cleaning procedure.
b) If TensION shows no indication of voltage on any points, perform power
supply test (see below).
c) If it is determined that the power supply is operative, and more than one
static bar is in use, locate the faulty bar.
Содержание Simco-Ion Ion-O-Vac
Страница 1: ...Ion O Vac 5200860 Rev H INSTALLATION AND OPERATING INSTRUCTIONS Ion O Vac Web Sheet Cleaners ...
Страница 12: ...10 5200860 Rev H Ion O Vac Figure 6 Variable Speed Control General Dimensions Penta Drive ...
Страница 23: ...21 5200860 Rev H Ion O Vac 10 DIMENSIONAL DRAWINGS An ITW Company ...
Страница 24: ...22 5200860 Rev H Ion O Vac An ITW Company ...
Страница 25: ...23 5200860 Rev H Ion O Vac An ITW Company ...
Страница 26: ...24 5200860 Rev H Ion O Vac An ITW Company ...
Страница 27: ...25 5200860 Rev H Ion O Vac An ITW Company ...
Страница 28: ...26 5200860 Rev H Ion O Vac An ITW Company ...
Страница 29: ...27 5200860 Rev H Ion O Vac An ITW Company ...
Страница 30: ...28 5200860 Rev H Ion O Vac An ITW Company ...
Страница 31: ...29 5200860 Rev H Ion O Vac An ITW Company ...
Страница 32: ...30 5200860 Rev H Ion O Vac An ITW Company ...
Страница 33: ...31 5200860 Rev H Ion O Vac An ITW Company ...
Страница 34: ...32 5200860 Rev H Ion O Vac An ITW Company ...
Страница 35: ...33 5200860 Rev H Ion O Vac An ITW Company ...