11
5200860 Rev H
Ion-O-Vac
5. WIRING
Magnetic Starter & Blower Motor
The magnetic starter is shipped with the overload relay already installed. For
wiring instructions for the Siemens’ magnetic starter, see Print #202-0041-00. For
installation of the Reset Button on a Siemens’ magnetic starter, refer to Figure 9.
Figure 8. Magnetic Started General Dimensions (Siemens)
Figure 9. Reset Button installation (Siemens)
Remove the knockout in the cover or door and measure the dimension “X”. Add
0.19 inches/5 mm to length “X”. Cut or break off the extension rod to the next