SERVICE MANUAL SPIKA SERIES
17
Analogical inputs
Symbol
Description
ESP
Thickness detection sensor
NW
Water level in reservoir
EAL
NTC 10K suction temperature probe
Connector for double layer stacking of 2 machines
Symbol
Description
CO1
Con jumper for indication of the lower machine
LED signalling
Symbol
Description
LO 1-6
6 orange LEDs for each output
LI 1- 7
7 green LEDs for each input
LE 1-4
4 red LEDs for status/alarm (flashing) stand by
– ice – full - wash
5.3. Alarms
They detect operational malfunctions. They are indicated with the flashing status LEDs LE1-4.
During some alarms a second operation retry attempt is carried out and if repeated again, the
machine will stop. Signaling should be indicated since the first failure occurs. If the second retry
attempt is ok, the signaling must be switched off.
In case that a machine stop has been caused by alarm, the resetting is done by disconnecting
or by switching over to position 0. If the dip-switch 2 ON, time alarms are not to be followed.
5.4. Safety pressure
When the pressure contact (P) is open, instantly, all outputs switch over to off position.
When it is closed again, there are two possibilities:
- Dip-switch 1 OFF. Manual reset. The machine remains stopped until reset
Initial start-up.
- Dip-switch 1 ON. Automatic reset. The machine will stop for a time t5, then continue at the
position where it was, except during the harvesting phase, that has an initial start. If starts at
fabrication, the hot gas valve will open during time t20 before starting the compressor.
* Signaling: Flashing in the four LEDs.
Содержание SPIKA MS 1000
Страница 29: ...SERVICE MANUAL SPIKA SERIES 29 7 TECHNICAL SPECIFICATIONS SPIKA NG UNDERCOUNTER SPIKA MODULAR Z X Y X Z Y ...
Страница 39: ...SERVICE MANUAL SPIKA SERIES 39 9 WIRING DIAGRAMS 9 1 SPIKA NG under counter models ...
Страница 40: ...SERVICE MANUAL SPIKA SERIES 40 9 2 SPIKA MS 700 ...
Страница 41: ...SERVICE MANUAL SPIKA SERIES 41 9 3 SPIKA MS 500 AND SPIKA MS 1000 A W ONE PHASE ...
Страница 42: ...SERVICE MANUAL SPIKA SERIES 42 9 4 SPIKA MS 1000 THREE PHASES ...