SERVICE MANUAL SPIKA SERIES
11
For under counter machines: In case the room temperature exceeds 85ºF (29.5ºC) or water
inlet temperature exceeds 68ºF (20ºC) the following adjustments should be made to ensure a
proper efficiency.
REGULATION/CALIBRATION CYCLE AND STOCK THERMOSTATS
MODEL
REGULATION / CALIBRATION
CYCLE THERMOSTAT
STOCK THERMOSTAT
SPIKA
SPIKA NG 125 W
3.5
5.5
SPIKA NG 125 A
3.5
5.5
SPIKA NG 175 W
3.5
5.5
SPIKA NG 175 A
3.5
5.5
SPIKA NG 215 W
3
5.5
SPIKA NG 215 A
3
5.5
SPIKA NG 285 W
3
5.5
SPIKA NG 285 A
3
5.5
NOTE:
The thermostat regulation may vary depending on the ambient temperature of water and
on the place where the machine has been installed. By default, the factory
–set regulation
covers a wide range of temperatures.