SERVICE MANUAL SPIKA SERIES
20
- Closed jumper
upper machine
- Open jumper
lower machine
The lower machine works in the same way as if operating alone.
The upper machine operates normally except when the lower machine is stopped due to full
storage (full), at this moment, the upper machine will also stop and pass over to the same status
(full).
When the curtain of the lower machine is closed again, it re-initiates the start-up sequence,
likewise the upper machine, but with a 1’ delay.
6. MAINTENANCE AND CLEANING PROCEDURES
It is the User’s responsibility to keep the ice machine and ice storage bin in a sanitary condition.
Ice machines also require occasional cleaning of their water systems with a specifically
designed chemical. This chemical dissolves mineral build up that forms during the ice making
process.
Sanitize the ice storage bin as frequently as local health codes require, and every time the ice
machine is cleaned and sanitized.
The ice machine’s water system should be cleaned and sanitized at least twice a year.
CAUTION:
Do not mix Ice Machine Cleaner and Sanitizer solutions together.
WARNING:
Wear rubber gloves and safety goggles when handling Ice Machine Cleaner or
Sanitizer.
WARNING:
Unit should always be disconnected during maintenance/cleaning procedures.
6.1. Cleaning water distribution system for under counter models (NG)
a) Set the switch to the OFF position after ice falls from the evaporator at the end of a
harvest cycle, or set the switch to the OFF position and allow the ice to melt off the
evaporator.
CAUTION:
Never use anything to force ice from the evaporator.
b) Remove all ice from the bin.
Содержание SPIKA MS 1000
Страница 29: ...SERVICE MANUAL SPIKA SERIES 29 7 TECHNICAL SPECIFICATIONS SPIKA NG UNDERCOUNTER SPIKA MODULAR Z X Y X Z Y ...
Страница 39: ...SERVICE MANUAL SPIKA SERIES 39 9 WIRING DIAGRAMS 9 1 SPIKA NG under counter models ...
Страница 40: ...SERVICE MANUAL SPIKA SERIES 40 9 2 SPIKA MS 700 ...
Страница 41: ...SERVICE MANUAL SPIKA SERIES 41 9 3 SPIKA MS 500 AND SPIKA MS 1000 A W ONE PHASE ...
Страница 42: ...SERVICE MANUAL SPIKA SERIES 42 9 4 SPIKA MS 1000 THREE PHASES ...