w) Switch on compressor switch (I position)
x) Return the back metal lid and the top panel to their position.
y) Switch on machine and discard the first two harvests.
6.2. Cleaning water distribution system for modular models (MS)
1) Remove the front panel.
2) Set Ice-wash switch to the OFF position (position 0) after ice falls from the evaporator at
the end of a harvest cycle, or set the ice-wash switch to the OFF position and allow the
ice to melt off the evaporator.
CAUTION:
Never use anything to force ice from the evaporator. Damage may result.
3) Prepare a solution of an appropriate product for the cleaning of ice machines (lime). Do
not use hydrochloric acid. We recommend the use of any NSF approved scale removal
product. In modular machines the water bucket is filled automatically so we recommend
to prepare a previous solution (for example 0.15 gal,
according to the manufacturer’s
instructions with the total quantity of product needed for the water tray 0.8 gal for MS 500
and 1.6 gal for MS 1000 and 0.9 gal for MS 700).
To start a cleaning cycle, move the ice-wash switch to the WASH position (position II).
The machine will drain the reservoir and refill it. Pour the scale remover solution into the
reserve.
Front panel
Содержание SPIKA MS 1000
Страница 29: ...SERVICE MANUAL SPIKA SERIES 29 7 TECHNICAL SPECIFICATIONS SPIKA NG UNDERCOUNTER SPIKA MODULAR Z X Y X Z Y ...
Страница 39: ...SERVICE MANUAL SPIKA SERIES 39 9 WIRING DIAGRAMS 9 1 SPIKA NG under counter models ...
Страница 40: ...SERVICE MANUAL SPIKA SERIES 40 9 2 SPIKA MS 700 ...
Страница 41: ...SERVICE MANUAL SPIKA SERIES 41 9 3 SPIKA MS 500 AND SPIKA MS 1000 A W ONE PHASE ...
Страница 42: ...SERVICE MANUAL SPIKA SERIES 42 9 4 SPIKA MS 1000 THREE PHASES ...