Reassembly
Model 710 TruBlue Installation, Operation, and Maintenance Manual
64
Install the impeller
CAUTION:
Risk of physical injury from sharp edges. Wear heavy work gloves when handling impellers.
For the fitting threads and for tight tolerances, use a suitable anti-seize compound. Use this, for
example, between the shaft sleeve and the shaft or between the impeller and the shaft. This
makes the assembly and the next disassembly easier to perform.
NOTICE:
Anti-seize compounds must be compatible with the pumped fluid.
Perform these steps in order to install the impeller:
1. Insert the impeller key (178) in the shaft (122).
2. Slide the impeller (101) onto the shaft.
3. Secure the rotor at the coupling end and tighten the impeller nut (304) (right-threaded).
4. Tighten the impeller nut to the torques listed in the Torque values table.
NOTICE:
Crush hazard. Make sure that the back pull-out assembly cannot tip over.
Install the back pull-out assembly
WARNING:
Lifting and handling heavy equipment poses a crush hazard. Use caution during lifting and
handling and wear appropriate Personal Protective Equipment (PPE, such as steel-toed shoes,
gloves, etc.) at all times. Seek assistance if necessary.