Installation
Model 710 TruBlue Installation, Operation, and Maintenance Manual
16
Installation
Pre-installation
Precautions
WARNING:
All equipment being installed must be properly grounded to prevent unexpected discharge.
Discharge can cause equipment damage, electric shock, and result in serious injury. Test the
ground lead to verify it is connected correctly.
NOTICE:
• Electrical connections must be made by certified electricians in compliance with all
international, national, state and local regulations.
• Supervision by an authorized ITT representative is recommended to ensure proper
installation. Improper installation may result in equipment damage or decreased perfor-
mance.
Pump location guidelines
Guideline
Explanation/comment
Keep the pump as close to the liquid
source as practically possible.
This minimizes the friction loss and keeps the suction piping
as short as possible.
Make sure that the space around the
pump is sufficient.
This facilitates ventilation, inspection, maintenance, and ser-
vice.
If you require lifting equipment such as a
hoist or tackle, make sure that there is
enough space above the pump.
This makes it easier to properly use the lifting equipment and
safely remove and relocate the components to a safe location.
Protect the unit from weather and water
damage due to rain, flooding, and freez-
ing temperatures.
This is applicable if nothing else is specified.
Do not install and operate the equipment
in closed systems unless the system is
constructed with properly-sized safety
devices and control devices.
Acceptable devices:
• Pressure relief valves
• Compression tanks
• Pressure controls
• Temperature controls
• Flow controls
If the system does not include these devices, consult the
engineer or architect in charge before you operate the pump.
Take into consideration the occurrence of
unwanted noise and vibration.
The best pump location for noise and vibration absorption is
on a concrete floor with subsoil underneath.
Foundation requirements
Requirements
• The foundation must be able to absorb any type of vibration and form a permanent, rigid
support for the unit.
• The location and size of the foundation bolt holes must match those shown on the
assembly drawing provided with the pump data package.
• The foundation must weigh between two and three times the weight of the pump.
• Provide a flat, substantial concrete foundation in order to prevent strain and distortion
when you tighten the foundation bolts.