Disassembly
Model 710 TruBlue Installation, Operation, and Maintenance Manual
55
NOTICE:
Crush hazard. Make sure that the back pull-out assembly cannot tip over.
Remove the seal-chamber cover
1. Remove the gland stud nuts.
2. Remove the seal-chamber stud nuts.
3. Remove the seal chamber (184).
4. Remove the cartridge seal.
The seal is set screwed to the shaft. Be sure to remove the set screws before moving the
seal.
Figure 23: Gland removal
Disassemble the power end
1. Loosen and remove the hexagon bolts (370B) (not shown below, refer to the cross
sectional drawing) that hold the frame adapter to the bearing frame.
2. Remove the frame adapter (108) from the bearing frame (228).
Figure 24: Bearing frame cross-section