Commissioning, Startup, Operation, and Shutdown
Model 710 TruBlue Installation, Operation, and Maintenance Manual
37
1. De-energize the motor, place the motor in a locked-out position, and place a caution tag at
the starter that indicates the disconnect.
2. Put the pump-half of the coupling guard in place:
a) Slightly spread the bottom apart.
b) Place the coupling guard half over the pump-side end plate.
Item Description
1.
Annular groove
2.
Pump-side end plate
3.
Driver
4.
Pump half of the coupling guard
Figure 15: Guard half installation
The annular groove in the coupling guard half must fit around the end plate.
Item Description
1.
Annular groove
2.
End plate (pump end)
2.
Guard half
Figure 16: Annular groove in coupling guard