i-ALERT2 Application Guide
50 of 64
COMMANDS
Occasionally the need may arise to refresh the i-ALERT2 devices stored data. For instance after a machine is repaired or if a
device is moved to another piece of equipment. The “Commands” page contains commands that can be sent to update or
refresh the i-ALERT2 monitor as necessary.
Figure 48: Allowed commands
A brief description of each command is listed below:
Put i-ALERT into sleep Mode
: device will go into a very low power consumption mode and does not acquire any data until it
is awakened. (Note: A magnet is needed to reawaken the system.)
Start New Baseline
: Tells the i-ALERT2 monitor to perform the baseline procedure to establish new Alarm/Warning limits.
The device will perform a series of measurements over approximately a day of running to calculate its new baseline.
Erase all stored data from i-ALERT:
Completely erases all stored measurement data. Can be used to “wipe” an i-ALERT if it
is being transferred to another machine.
Содержание i-ALERT2
Страница 1: ...Application Guide...
Страница 2: ...i ALERT2 Application Guide 2 of 64...
Страница 32: ...i ALERT2 Application Guide 32 of 64 Figure 27 Devices in range and out of range...
Страница 38: ...i ALERT2 Application Guide 38 of 64 Figure 33 Export trend data by printing or attaching to email...
Страница 58: ...i ALERT2 Application Guide 58 of 64 Figure 57 Route Report Trend Details Screen...
Страница 63: ...i ALERT2 Application Guide 63 of 64...
Страница 64: ...i ALERT2 Application Guide 64 of 64 G iALERT2AppGuide en US 2016 10...