i-ALERT2 Application Guide
24 of 64
BETWEEN BEARINGS PUMP
On between bearings pumps, it is recommended to mount i-ALERT2 monitors to both bearing housings. If only one device is
to be installed on a pump, then it should be installed on the bearing housing that contains the thrust bearing. Note, that
this is not always the drive end bearing housing. Be sure to check the pumps cross sectional drawing to verify location of
the thrust bearing.
Figure 18: Double Suction , Horizontal Split case pump, mounted on thrust bearing housing
Figure 17: Between Bearings Pump (BB3), mounted on each bearing housing
Содержание i-ALERT2
Страница 1: ...Application Guide...
Страница 2: ...i ALERT2 Application Guide 2 of 64...
Страница 32: ...i ALERT2 Application Guide 32 of 64 Figure 27 Devices in range and out of range...
Страница 38: ...i ALERT2 Application Guide 38 of 64 Figure 33 Export trend data by printing or attaching to email...
Страница 58: ...i ALERT2 Application Guide 58 of 64 Figure 57 Route Report Trend Details Screen...
Страница 63: ...i ALERT2 Application Guide 63 of 64...
Страница 64: ...i ALERT2 Application Guide 64 of 64 G iALERT2AppGuide en US 2016 10...