b) Lift upwards.
5.
Remove the remaining nut, bolt, and washers from the pump half of the coupling guard.
It is not necessary to remove the end plate from the pump side of the bearing housing. You can
access the bearing-housing tap bolts without removing this end plate if maintenance of internal
pump parts is necessary.
6.
Remove the pump half of the coupling guard:
a) Slightly spread the bottom apart.
b) Lift upwards.
1
2
3
4
Item Description
1.
Pump half of the coupling guard
2.
Annular groove
3.
Deflector fan guard
4.
Driver
Figure 14: Coupling guard
5.3 Check the rotation
WARNING:
•
Starting the pump in reverse rotation can result in the contact of metal parts, heat genera-
tion, and breach of containment. Ensure correct driver settings prior to starting any pump.
•
Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any installa-
tion or maintenance tasks.
•
Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
•
Refer to driver/coupling/gear manufacturer's installation and operation manuals
(IOM) for specific instructions and recommendations.
1.
Lock out power to the driver.
5.3 Check the rotation