NOTICE:
The specified permitted reading values are valid only at operating temperature. For cold set-
tings, other values are permitted. The correct tolerances must be used. Failure to do so can
result in misalignment. Contact ITT for further information.
4.3.5.4 Perform parallel alignment for a horizontal correction
A unit is in parallel alignment when the parallel indicator (P) does not vary by more than as measured at
four points 90° apart at the operating temperature.
1.
Set the parallel alignment indicator (P) to zero on the left side of the driver coupling half (Y), 90°
from the top-center position (9 o’clock).
2.
Rotate the indicator through the top-center position to the right side, 180° from the start position
(3 o’clock).
3.
Record the indicator reading.
When the reading value is... Then...
Negative
The driver coupling half (Y) is to the left of the pump coupling half (X).
Positive
The driver coupling half (Y) is to the right of the pump coupling half (X).
4.
Slide the driver carefully in the appropriate direction.
NOTICE:
Make sure to slide the driver evenly. Failure to do so can negatively affect horizontal angular
correction.
5.
Repeat the previous steps until the permitted reading value is achieved.
4.3.5.5 Perform complete alignment for a vertical correction
1.
Set the angular and parallel dial indicators to zero at the top-center position (12 o’clock) of the driver
coupling half (Y).
2.
Rotate the indicators to the bottom-center position (6 o’clock).
3.
Record the indicator readings.
4.
Make corrections according to the separate instructions for angular and parallel alignment until you
obtain the permitted reading values.
4.3.5.6 Perform complete alignment for a horizontal correction
1.
Set the angular and parallel dial indicators to zero at the left side of the driver coupling half (Y), 90°
from the top-center position (9 o’clock).
2.
Rotate the indicators through the top-center position to the right side, 180° from the start position
(3 o’clock).
3.
Record the indicator readings.
4.
Make corrections according to the separate instructions for angular and parallel alignment until you
obtain the permitted reading values.
4.4 Grout the baseplate
Required equipment:
•
Cleaners: Do not use an oil-based cleaner because the grout will not bond to it. See the instructions
provided by the grout manufacturer.
4.4 Grout the baseplate
Model 3355 Installation, Operation, and Maintenance Manual
29