c) Remove the wearing cover.
Install the impeller
WARNING:
If you fail with the impeller installation, you must redo the installation procedure from the beginning.
1. Prepare the sleeve:
a) Make sure that the end of the shaft is free from burrs.
Polish off any flaws with a fine emery cloth.
b) Grease the shaft end.
c) Grease the conical sleeve, the threads of the adjustment screw, the washer, and the impeller screw.
NOTICE:
The impeller can become loose. Remove any surplus grease from conical and cylindrical surfaces
of shafts and sleeves.
d) Adjust the adjustment screw so that it is flush with the sleeve.
2. Mount the impeller:
a) Assemble the wearing cover to the drive unit and secure it with a round sling.
Maintenance (Continued)
Flygt 5150.350, 5150.360 Installation, Operation, and Maintenance Manual
33