Maintenance
Precautions
WARNING:
• Always follow safety guidelines when working on the pump. See
(page 3).
• Disconnect and lock out electrical power before installing or servicing the pump.
• Make sure that the pump cannot roll or fall over and injure people or damage property.
• Rinse the pump thoroughly with clean water before working on the pump.
• Rinse the components in water after dismantling.
Make sure that you follow these requirements:
• Check the explosion risk before you weld or use electrical hand tools.
• Allow all system and pump components to cool before you handle them.
• Make sure that the product and its components have been thoroughly cleaned.
• Do not open any vent or drain valves or remove any plugs while the system is pressurized. Make sure
that the pump is isolated from the system and that pressure is relieved before you disassemble the
pump, remove plugs, or disconnect piping.
Maintenance guidelines
During maintenance and before reassembly, always remember to perform these tasks:
• Clean all parts thoroughly, particularly O-ring grooves.
• Change all O-rings, gaskets, and seal washers.
• Lubricate all springs, screws, and O-rings with grease.
During reassembly, always make sure that existing index markings are in line.
The reassembled drive unit must always be insulation-tested and the reassembled pump must always be test-
run before normal operation.
Torque values
Screw and nuts
Stainless steel, A2 and A4
Property
class
M4
M5
M6
M8
M10
M12
M16
M20
M24
M30
Torque,
Nm (ft-
lbs)
70 +80
1
2.7 (2)
5.4 (4)
9.3 (6.9) 22 (16)
44 (32)
76 (56)
187 (138) 364 (268) 629 (464) 1240
(915)
Carbon steel and alloyed steel
1
Property class 70 is torque tightened as class 80.
Maintenance
Flygt 5150.350, 5150.360 Installation, Operation, and Maintenance Manual
27
Содержание Flygt 5150.350
Страница 1: ...Water Wastewater Installation Operation and Maintenance Manual Flygt 5150 350 5150 360...
Страница 2: ......
Страница 47: ......