English
6
Code 1625186897- Edition 7/2019
1 SUCTION FILTER
10 OIL FILTER
2 SUCTION REGULATOR
11 AIR-OIL SEPARATOR
3 SCREW COMPRESSOR
12 AIR-OIL COOLER
4 TEMPERATURE SENSOR
13 PRESSURE TRANSDUCER
5 CONTROLLER
14 BELT PULLY
6 OIL DISCHARGE VALVE
15 ELECTRIC MOTOR
7 AIR-OIL PRESEPARATOR
16 FAN
8 OIL SEPARATOR SEAT
9 SAFETY VALVE
4.0 GENERAL SAFETY STANDARDS
The appliance may be used only by specially trained and authorized personnel.
Any with the machine or alterations not approved
beforehand by the Manufacturer relieve the latter of responsibility for any damage resulting from the
above actions.
ATTENTION: UPSTREAM OF THE MACHINE INSTALLAN ISOLATOR KNIFE-SWITCH WITH AN
AUTOMATIC CUTOUT AGAINST CURRENT SURGES AND EQUIPPED WITH A DIFFERENTIAL
DEVICE FOR CALIBRATIONS SEE WIRING DIAGRAM ON LAST PAGE
ALL WORK ON THE ELECTRIC PLANT, HOWERE SLIGHT, MUST BE CARRIED OUT BY
PROFRSSIONALLY SKILLED PERSONEL.
5.0 DESCRIPTION OF DANGER SIGNALS
1
2
3
6
7
10
12
13
9
11
8
5
15
4
14
16
1)
FLUID EJECTION
5)
HIGH PRESSURE
FIG. 3
FIG. 2