BEFORE DRAINING THE CONDENSATE IT IS OBLIGATORY TO STOP THE MACHINE
AND DISCONNECT IT FROM THE POWER MAINS.
Proceed as follows:
- Press the “STOP” button Ref. 2 Fig. 16
- Turn the isolating switch and block it with the padlock.
- Turn on the supply automatic differential switch.
- Wait for the machine to cool down.
- Remove the panels with the key provided.
- SLOWLY turn on the tap Ref. 3 Fig. 16 and let the condensate flow out.
- When the first traces of oil appear, turn off the tap.
CONDENSATE MUST BE DISPOSED OF IN CONFORMITY WITH THE LOCAL
REGULATIONS IN FORCE.
- Check the oil level on the indicator Ref. 4 Fig. 16
- If the oil level is low, top up as described in 15.4
USE OIL OF THE SAME TYPE AS THAT ALREADY IN THE MACHINE; DO NOT MIX
DIFFERENT TYPES OF OIL
15.3 MAINTENANCE SCHEDULE
OPERATIONS THAT MAY BE CARRIED OUT BY THE USER
OPERATIONS THAT REQUIRE SKILLED PERSONNEL
These maintenance intervals are recommended for work environments that are not dusty and are well
ventilated.
For particularly dusty environments, double the frequency of intervals.For more information please
contact manufacturer or nearest dealer
Running time
Plan
Content
Every 50 hours
(Daily/Weekly)
Check the temperature reading.
Check the oil level
Clean the filtering panel
Check for possible air or oil leaks.
Every 500 hours
(OR monthly)
A
Clean the air suction filter
(see control board LED)
Check belt tension
Drain condensate from separator tank
Change the oil
(see control board LED)