English
28
Code 1625186897- Edition 7/2019
15.6 CLEANING THE SUCTION FILTER OR CHANGING THE FILTER
- Press the “STOP” button Ref. 2 Fig. 16
- Press the “EMERGENCY STOP” Ref. 5 Fig. 5.
- Turn the power off from the mains.
HOT PARTS INSIDE
- Remove the cover Ref. 7 Fig. 17a.
- Remove the filter Ref. 8 Fig. 17a.
AVOID DROPPING FOREIGN BODIES INTO THE SUCTION MANIFOLD.
- Clean the filter with a jet of air, working from inside to outside.
DO NOT USE WATER OR
SOLVENTS
. Fit a new filter if required.
- Clean the disk on which the filter rests with a clean cloth.
- Fit the filter and the cover.
- Dispose of the old filter in conformity with the local regulations in force.
15.7 CHANGING THE OIL (see 18.0 part number for oil.)
BEFORE CARRYING OUT ANY MAINTENANCE JOBS IT IS OBLIGATORY TO STOP THE
MACHINE AND DISCONNECT IT FROM THE POWER MAINS AND FROM THE
COMPRESSED AIR DISTRIBUTION NETWORK.
Oil changing is an important operation for the compressor:
The oil must be changed when the machine is still warm, that is immediately after stopping it.
The suggestions listed below should be carefully followed.
After draining the old oil out of the machine Ref. 2 Fig. 18.
- Completely fill the oil collector , observe level on sight glass Ref. 1 Fig. 18.
- Start the compressor.
- After about 1 minute switch off the machine by pressing “STOP” (Ref. 2 Fig. 16).
(machine will switch off after a few seconds of idle running.)
AFTER THIS STEP PROCEED AS DESCRIBED IN CHAPTER 15.4
FIG. 17
cleaning
FIG. 17a