9.0 COMPRESSOR ROOM
9.1 FLOOR
The floor must be even and of industrial type for the total weight of the machine(Please refer to
technical data)..
Remember the total weight of the machine when positioning it. (See chapter 13.0)
9.2 VENTILATION
When the machine is operating, the room temperature must not be higher than
40 °C
or lower than
1 °C.
The volume of the room must be about
30 m
3
The room must be provided with 2 openings for ventilation with a surface area of about
0,3 m
2
each.
The first opening must be in a high position to evacuate the hot air, the second opening must be low to
allow the intake of external air for ventilation.
If the environment is dusty it is advisable to fit a filtering panel for this opening.
The hot air ejected by the compressor may be led outside with a duct.
This duct must have a minimum section of
0,5 m
2
and it must not be longer than
2 m.
For longer ducts an extra exhaust fan must be fitted.
9.3 EXAMPLES OF VENTILATION OF THE COMPRESSOR ROOM
FIG. 8
FAN AIR OUTPUT
HOT AIR EJECTION
HOT AIR PIPE
ATTENTION: REMOVABLE PIPE TO
ALLOW CLEANING OF THE
RADIATOR