Technical Specifications
Copyright ©ITECH Electronic Co., Ltd.
80
DC Output
Temperature
coefficient
< 100ppm/
℃
F.S
Current setting
1phase
-30
~
30
Adc
Resolution
0.01
A
Accuracy
<
0.3%+0.3% F.S
Temperature
coefficient
< 200ppm/
℃
F.S
Max. power
Total power
Max. Power
(
1phase
)
3k
W
Programmable
impedance
Range
0Ω+200µH
~
1Ω+1mH
Voltage stability
Line regulation
<
0.05% F.S.
Load regulation
DC,16Hz
~
500Hz
<
0.05% + 0.05% F.S.
500.01Hz
~
2.4Hz
<
0.05% + (0.1%*kHz) F.S
THD
16Hz
~
100Hz
<
0.5%
100.01Hz
~
500Hz
<
1%
500.01Hz
~
2.4kHz
<
1%+(1%*kHz) F.S
Voltage ripple
RMS
< 0.4
V
Dynamic response
*4
typ
200
us
Voltage Slew
Rate,
Typical
≥2 V/µs with full-scale programmed voltage step
Output Isolation
550Va
c
Measurement parameter
Voltage RMS
Resolution
0.01
V
Accuracy
DC,16Hz
~
500Hz
<
0.1%+0.1% F.S.
500.01Hz
~
2.4kHz
<
0.1%+(0.2%*kHz) F.S
emperature coefficient
< 100ppm/
℃
F.S.
Current RMS
Resolution
0.01
A
Accuracy
16Hz
~
150Hz
<
0.1%+0.2% F.S
150.01Hz
~
500Hz
<
0.2%+0.3% F.S
500.01Hz
~
2.4kHz
<
0.3%+(0.6%*kHz) F.S
Temperature
coefficient
< 200ppm/
℃
F.S.
Peak current
Resolution
0.01
A
Accuracy
DC,16
~
500Hz
<
0.4% + 0.6% F.S.
500.01Hz
~
2.4kHz
<
0.4% + (1.2%*kHz) F.S
Output power
Resolution
0.001
kW
Accuracy
DC,16
~
500Hz
<
0.4% +0.4% F.S.
500.01Hz
~
2.4kHz
<
0.4% +(0.8%*kHz) F.S
Harmonic
measurement
Max.
50/60Hz
up to 50
order
s
Others
Efficiency
typ
88%
Protection
OVP, OCP, OPP, OTP, FAN, Sense
Working
0
℃
-
50
℃
Programming
response time
2ms
Remote Sense
Compensation
20V