System-Related Functions
Copyright ©ITECH Electronic Co., Ltd.
47
Phase control
Phase difference between AB and AC, only
valid in balance control is Off state.
AB: Phase difference between A and B.
AC: Phase difference between A and C.
Waveform
Selece and edit the output wave type. For
detailed introduction please refer to 4.3
waveform selection.
Dimming
Status: Dimming function switch.
E
dge: select front edge or back adge
Phase: phase control, range from 0-180°
AC+DC
Config
Configuration setting for AC+DC mode
Balance control
Only displayed in 3-phase mode.
Balance control in 3-phase mode.
If select On, the output of ABC phase is
synchronous.
If select Off, the output is not balanced.
Voltage AC
Output voltage
Vac: output voltage of AC, range from 0-full
scale
Slew Rate: Slope , range from 0.001-
5000V/ms
Voltage DC
Output voltage of DC, range from 0-10% of
full scale
Slew Rate: Slope , range from 0-5000V/ms
Frequency
Freq: output frequency, range from 16-
2400Hz
Slew Rate: slope, range from 0.001-
5000Hz/ms
Waveform
Selece and edit the output wave type. For
detailed introduction please refer to 4.3
waveform selection.
Dimming
Status: Dimming function switch.
E
dge: select front edge or back adge
Phase: phase control, range from 0-180°
Balance Control Setting
In three-phase mode, the instrument is in three-phase balance mode by default,
and the three-phase output voltage will be set synchronously, and the phase
Angle between phases is fixed at 120°, which cannot be set.
You can set the Balance Control to Off and disable the Balance control function
in the Config menu. And then, the voltage of each phase can be set
independently, and the config menu displays the phase Angle difference setting
parameter between AB and AC.
Dimming Function
The front and back edge of the waveform can by concealed and the phase
angle set with Dimmer function to regulate the active power, thus
adjusting the lighting intensity.